Page 17
Assembly Instructions
knightgroup.co.nz
Agile Pro
Electric 3 Column Double Sided Desk
Error Code Meaning and Trouble Shooting
Code
Message
Required Actions
rES
Manual Resetting
Refer to the progress of manual reset.
E-1
Manual Resetting
Refer to the progress of manual reset.
E-2
Anti-Collision Function
Once the desktop or frame encounters any obstacle in its path, the
displays shows “E-2” and the desktop will automatically move a defined
distance in opposite direction, it would be used normally after removing
the obstacle.
E-3
Motor Cable
Disconnected
Disconnect the Control Box from the Mains. Fix the external short circuit.
Ensure all cables are connected correctly. Reconnect the system, then
operate as normal.
E-4
Height Difference
After moving, the height between the two columns exceeds 1 inch, stop
any operation and execute the Manual Reset procedure.
ovr
Overloading
Remove the load on desktop till it less than 1400N (315 LBS) for further
operation.
dut
Operated continuously
without suitable rest
Make the desk rest around 18minutes for further operation. The display
will show alternately as “dut” and a countdown number. For example,
“dut” & “013” means that there are 13 minutes before reuse.
NOTICE
Usually the display alternately shows two error code, such as “E-1”/“rES”, “E-3”/“rES”, “E-4”/“rES”, that means
you need to execute the Manual Reset procedure after completing the required actions.
NOTICE
Do not operate the table system if problems persist. Contact Knight for further information.
Technical Data
Item
Data
Input Voltage
AC 100~240V 50/60Hz
Output Voltage
DC 24V
Max Loading
1400N
Height Range (Including worktop)
625 - 1275mm
Duty Cycle
2 min on / 18 min off