P45000
23
6 Specifications
6.1 Input
Measuring ranges/Output ranges
Product variant
Rated voltage Nominal measuring range Nominal output range Type test voltage
Product without SIL
P45000K2***/0500
1)
500 V
±500 V
±50 mA
10 kV
P45000K2***/0750
1)
750 V
±750 V
±50 mA
10 kV
P45000K2***/1000
1)
1000 V
±1000 V
±50 mA
10 kV
P45000K2***/1500
1)
1500 V
±1500 V
±50 mA
10 kV
P45100K2***/0500
1)
500 V
±500 V
±50 mA
20 kV
P45100K2***/0750
1)
750 V
±750 V
±50 mA
20 kV
P45100K2***/1000
1)
1000 V
±1000 V
±50 mA
20 kV
P45100K2***/1500
1)
1500 V
±1500 V
±50 mA
20 kV
P45100K2***/2000
1)
2000 V
±2000 V
±50 mA
20 kV
P45100K2***/2800
1)
2800 V
±2800 V
±50 mA
20 kV
P45100K2***/3000
1)
3000 V
±3000 V
±50 mA
20 kV
Products with SIL/EN 61508
P45011K2***/0500
1)
500 V
0
…
500 V
10
…
50 mA
10 kV
P45011K2***/0750
1)
750 V
0
…
750 V
10
…
50 mA
10 kV
P45011K2***/1000
1)
1000 V
0
…
1000 V
10
…
50 mA
10 kV
P45011K2***/1500
1)
1500 V
0
…
1500 V
10
…
50 mA
10 kV
P45111K2***/0500
1)
500 V
0
…
500 V
10
…
50 mA
20 kV
P45111K2***/0750
1)
750 V
0
…
750 V
10
…
50 mA
20 kV
P45111K2***/1000
1)
1000 V
0
…
1000 V
10
…
50 mA
20 kV
P45111K2***/1500
1)
1500 V
0
…
1500 V
10
…
50 mA
20 kV
P45111K2***/2000
1)
2000 V
0
…
2000 V
10
…
50 mA
20 kV
P45111K2***/2800
1)
2800 V
0
…
2800 V
10
…
50 mA
20 kV
P45111K2***/3000
1)
3000 V
0
…
3000 V
10
…
50 mA
20 kV
Rated voltage according to EN 50163
U
n
= 600 V DC to 3000 V DC
Maximum measuring range
150 % of the nominal measuring range
Maximum permissible crest factor
1.5 related to nominal measuring range
Thermal overload capacity
Input rated voltage
Permanent overvoltage
Short-term overvolt-
age (max. 1 s, peak
value)
Input resistance R
in
±500 V
±750 V
±1500 V
2.7 MΩ
±750 V
±1500 V
±3000 V
5.4 MΩ
±1000 V
±1500 V
±3000 V
5.4 MΩ
±1500 V
±3000 V
±6000 V
10 MΩ
±2000 V
±3000 V
±6000 V
10 MΩ
±2800 V
±4500 V
±9000 V
16.8 MΩ
±3000 V
±4500 V
±9000 V
16.8 MΩ
Depending on the product variant and operating conditions, the maximum permissible voltages may be lower.
The section on isolation and the limits specified there must be taken into account.
1)
The individual product type can be determined from the order description, indicated on the narrow side of the
product (device front), and the product key.
Summary of Contents for P45000