P45000
25
6.6 Power Supply
Power supply
Rated voltage range
±15 V DC, ± 10%
…
±24 V DC, ± 10%
DC ripple upstream power supply
≤ 100 mV
p-p
Short-term interruption/undervoltage
Interruption class of the power supply unit ac-
cording to EN 50155
S1
Switchover class of the power supply unit accord-
ing to EN 50155
According to upstream power supply
Power consumption
0.8 W when supplied with ±15 V and I
out
= 0 mA
2.5 W when supplied with ±24 V and I
out
= ±50 mA
3.3 W when supplied with ±26.4 V and I
out
= ±75 mA
Inrush current per supply connection
0.0001 A²s = 100 µA²s
Reverse polarity protection
Reverse polarity protected
6.7 Isolation
Galvanic isolation
Input against output/power supply
2-port isolation
Type test
Test voltage P450**K2***
1)
10 kV AC for 1 min
Test voltage P451**K2***
1)
20 kV AC for 1 min
Surge voltage P450**K2***
1)
30 kV
Surge voltage P451**K2***
1)
50 kV
Routine test
Test voltage P450**K2****
1)
10 kV AC for 10 s
Test voltage P451**K2***
1)
16 kV AC for 10 s
Freedom from partial discharge
Extinction voltage (< 10 pC)
≥ 10 kV AC (50 Hz)
Overvoltage category
OV3
Pollution degree
P45***K2***
1)
PD2
P45***K2*1*
1)
PD3A
2)
(only EN 50124-1)
1)
The individual product type can be determined from the order description, indicated on the narrow side of the
product (device front), and the product key.
2)
Also note the requirements under