Installation
Swing Piston Pumps NPK 09
4
3. Installation
Pumps in the NPK 09 range are OEM models intended for
installation in equipment. When installing them make certain
that accident prevention regulations, and safety instructions,
including those for subsequent operation are observed. The
safety instructions in section 2 must be observed.
The dimensions of the mountings are given in Data Sheet E 300.
Install the pump so that the fan can draw in sufficient cooling air.
Install the pump so as accidental finger contact is with the fan is
impossible.
Fit the pump at the highest point in the system, so that condensate
cannot collect in the head of the pump - that prolongs working life.
When making the electrical installation the safety regulations
must be observed. In particular make sure that the electricity
supply is isolated before trying to connect the pump.
Compare the supply data with the data on the motor-plate. The
voltage must not vary by more than +10% and -10% from that
shown on the type-plate.
The earth (ground) wire must be connected to the motor (not
necessary on dc motors up to 24 V).
For brushed dc motor lead wires connection:
•
Red:
V+
•
Black:
Ground
Î
Incorrect lead wire connection will damage motor.
For brushless dc motor lead wire connection:
•
Red:
V+
•
Black:
Ground
•
White: Voltage control 0-5 V DC (4 wire motor only)
•
Green: Frequency output (4 wire motor only)
Î
Incorrect lead wire connection will damage motor.
In the electrical installation, arrangements (complying with EN
60335-1) must be made for disconnecting the pump motor from the
electrical supply.
The pump must be installed so that contact with live parts
(connection, possibly windings) is impossible.
We recommend that a fuse is installed in the supply circuit; the
operating current is given in Data Sheet E 300.
Remove the protection plugs from the port threads.
The accessories silencer/filter and hose connectors (where
applicable) are screwed into the port threads.
Connect the suction and pressure lines.
Arrange the suction and pressure lines so that condensate cannot
run into the pump.
Mechanical
Electrical
Caution:
Caution:
Pneumatic