Installation and connection
Swing Piston Pumps NPK 04
8
Translation of original Operating and Installation Instructions, english, KNF 121571-121574 06/14
The supplemental circuit must be structured according to the
following electrical diagram and the components defined therein in
order to achieve the required level of suppression
C1:
Capacitor
1 µF
C2:
Capacitor
1000 µF
L1:
Choke coil
6 µH
Fig. 1: Electrical diagram of the supplemental circuit
5.3. Pneumatic connection
Only connect components to the pump which are designed for
the pneumatic data of the pump (see Chapter4, Technical da-
ta).
If the pump is used as a vacuum pump, safely discharge the
pump exhaust.
Connecting pump
A marking on the pump head shows the direction of flow.
1. Remove the protective plugs from the hose connectors.
2. The accessory silencer/filter (where applicable) is put onto the
hose connector.
3. Connect the suction line and pressure line (tube ID 4 mm).
4. Lay the suction and pressure line at a downward angle to
prevent condensate from running into the pump.
Connected
components
Pump exhaust