![KMC Controls 44 Series Operator'S Manual Download Page 18](http://html.mh-extra.com/html/kmc-controls/44-series/44-series_operators-manual_1979518018.webp)
16
IMPORTANT!
1. Do not exceed maximum pump pressure rating (725 PSI).
2. Set pressure with outflow in bypass line only, all other discharge lines should be
closed.
3. If the oil in the site glass turns white, stop the pump immediately. Consult
TROUBLESHOOTING section of owner’s manual.
4. Do not leave water in pump during freezing conditions. Consult MAINTENANCE
AND ADJUSTMENTS section of owner’s manual.
Pump Warranty does not apply to damage caused by:
1. Exceeding maximum pump pressure.
2. Freeze damage.
3. Exceeding operating speed of 550 RPM.
4. Operating the pump with excessive angle at driveline/pump connection caused
by sharp turning radius.
5. Operating pump and damaged diaphragm (s).
6. Low oil level.