![Klugmann DORMAGEN Operating Instructions Manual Download Page 9](http://html1.mh-extra.com/html/klugmann/dormagen/dormagen_operating-instructions-manual_1979066009.webp)
A
≤
C-B -D
where:
A – height to which the angles should be pulled out,
B – distance from the hob to the lower surface of the hood,
C – distance from the ceiling to the hob,
D – distance from the lower surface of the hood to the top surface of the
hood.
5.3 GLASS ASSEMBLY
Put the glass on the hood body and then
tighten it with the screw (3) M4x20 with
a conical washer (2) and the rubber
washer (1). (Fig.8).
Fig.8
5.4 HOOD TO CEILING ASSEMBLY
Peel off the protective film from the masks. Place the masks on the hood
body with screwed angles and glass in such a way that the inner mask vents
are at the top. Before installation, make sure that the ceiling may transfer the
weight of the hood. Do not mount the hood directly to the plasterboard panels
of suspended ceilings. Clearly indicate the mounting location on the ceiling in
accordance with Figure 9. Spacing of the holes on the ceiling board is
204mm. The holes for fixing dowels should be drilled in the ceiling with
φ
8
mm drill. Fix the ceiling board to the ceiling by means of dowels (Note: Be
sure to use steel washers that are provided).