The air from the hood should not be discharged into the chimney
channel used to exhaust the appliances combusting gas or other fuels.
4.2 ELECTRICAL CONNECTION
Before connecting the hood to the power supply, make sure the voltage
and frequency of the supply current corresponds to that given on the
nameplate. The hood must be connected to an easily accessible outlet. It is
unacceptable to remove the plug and permanently connect the hood to power
supply. The hood must be connected to the power supply after this assembly.
5. ASSEMBLY
The distance "A" between the lowest part of the chimney hood and a
supporting surface of cooking utensils should be min. 65 cm for a gas stove
(Fig.4).
During assembly, observe the existing regulations for air evacuation.
When the chimney hood is used at the same time as appliances combusting
gas or other fuels, the room should be well ventilated.
In order to achieve optimal air evacuation use a rigid plastic duct with a cross-
section Ø150 mm or Ø120mm downstream the reducing union.
Fig. 4