klover DEA ECO 12 Manual Download Page 4

 

 

EN

G

LISH

 

INTRODUCTION 

Important security instructions

 

Read the following instructions prior to installing and using the product. 

 

 

 

Stove installation and initial start-up must be performed by expert personnel conscious of the 

importance of observing the applicable safety standards. Said personnel shall be responsible for 

the definitive installation of the device and its proper operation thereof.

 

KLOVER srl shall not be held liable if these precautions are not observed.

 

During installation of the device, all local regulations - included those referring to national and 

European Standards - must be observed.

 

  Connect the flue gas outlet to a flue having the features described in the 

Connections 

section of this 

User 

Guide.

 

  The device is not suitable for installation on a shared flue system. 

  If the flue should catch fire, employ appropriate systems for extinguishing the flames or call the fire 

brigade. 

  Connect the product to earthed sockets. Avoid using sockets controlled by switches or automatic timers. 

  Do not use a damaged or worn power supply cable. 

  If a multiple socket is used, make sure that the total voltage of the connected devices does not exceed 

the voltage supported by the socket. Furthermore, make sure that the total voltage of all devices 

connected to the socket does not exceed the maximum allowed level. 

  Do not use easily flammable substances to clean the device or its elements. 

  Do not leave flammable containers and substances in the room where the stove is installed. 

Do not use the device as an incinerator or for any use other than that for which it was designed.

  Do not use different fuels to those recommended. 

  Do not use liquid fuels. 

  The device - especially its external surfaces - becomes very hot to the touch during operation; handle it 

with caution in order to avoid burns. 

  Only use original spare parts recommended by the manufacturer. 

  Do not perform any unauthorised modification on the device. 

 

Using poor-quality pellets or pellets made of any other material may damage the stove's 

functions, besides voiding the warranty and the manufacturer's liability. 

  The Klover pellet products are not suitable for use  in smokeless zones.

  

 

A few precautions

 

  Do not touch any 

hot parts

 of the product (ceramic glass, flue pipe) during normal operation.

 

  Use the appropriate button to switch the electrical panel off. Do not disconnect the power supply cable 

while the stove is operating.

 

  Keep children away from the stove during normal operation, as they may suffer burns if they touch the 

stove's 

hot parts

 

  Children and inexperienced people must not be allowed to use the device.

 

 

NEVER open the door of the stove during normal operation.

 

 

 

Intended use

 

The automatic operation 

DEA ECO

 stove by Klover is designed for heating your entire home. 

The stove works exclusively with wood pellets and only with the hearth door shut. Never open the 

door while the device is operating. 

The stove comes with a DOUBLE COMBUSTION system guaranteeing “clean” flue gas emissions with 

among the lowest CO

2

 values in Europe, alongside excellent mean performance values. 

 

Do not use the stove in ways other than those indicated in this user guide. The stove is designed for 

indoor use only. 

 

This user guide constitutes an integral part of the stove. 

If the product is sold to another user, this manual must be handed down to the new owner. 

Summary of Contents for DEA ECO 12

Page 1: ...STUFA A PELLET DEA ECO 12 INSTALLAZIONE USO E MANUNTENZIONE CONSIGLI UTILI ITALIANO FRAN AIS ENGLISH ESPA OL Cod CS IST SE12 Rev 1 3 S R L Main Revision 1 3 FPH_supplement 001...

Page 2: ...9 FLUE AND CONNECTION TO THE LATTER STACK 10 ELECTRICAL CONNECTION 13 CLEANING AND MAINTENANCE 14 PRECAUTIONS BEFORE CLEANING 14 ROUTINE CLEANING 14 EXTRAORDINARY CLEANING 15 CLEANING THE CERAMIC GLA...

Page 3: ...or proper installation basic maintenance and control points which must be performed regularly furthermore it contains practical advice for obtaining maximum performance from the stove with minimum fue...

Page 4: ...for which it was designed Do not use different fuels to those recommended Do not use liquid fuels The device especially its external surfaces becomes very hot to the touch during operation handle it...

Page 5: ...s operational limits Regularly perform all maintenance activities Authorise expert and competent people to use the stove Failure to comply with the requirements of this guide shall automatically void...

Page 6: ...E GUIDE ONE WARRANTY COUPON ONE POWER SUPPLY CABLE This manual is an integral part of the machine if the stove is sold it must be handed down to the new owner AMBIENT TEMPERATURE SENSOR PELLET TANK SE...

Page 7: ...6 ENGLISH Connections data sheet S 80 mm M FLUE GAS OUTLET A 33 mm AIR EXTRACTION DEVICE E SWITCH WITH ELECTRIC CABLE CONNECTION REAR VIEW...

Page 8: ...imum draught Pa 12 1 12 1 Pellet tank capacity Kg 27 Pellet min max hourly consumption Kg h 2 81 0 51 Operating autonomy at minimum maximum output h 10 53 Flue pipe diameter mm 80 Nominal voltage V 22...

Page 9: ...conformity to international standards such as EN14961 2 DIN 51731 and O NORM M7135 are indicated on the packaging The packages are intact since pellets tend to absorb humidity Humidity not only reduce...

Page 10: ...measurements to be observed when positioning the stove in relation to the walls REAR WALL SIDE WALL SIDE WALL 50 cm 50 cm 10 cm Any shelves or false ceilings mounted above the stove must be at least 5...

Page 11: ...imney is essential to the efficient operation of a Klover appliance The chimney should be designed and constructed according to these instructions and relevant regulations including Building Regulatio...

Page 12: ...and initial vertical rise The flue system should run as vertically as possible as any deviations off the vertical can adversely affect the draw 45 is the maximum off vertical angle than may be used N...

Page 13: ...deciding whether a particular chimney design will provide sufficient draught The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulati...

Page 14: ...rom parts subject to high temperatures During the final wiring of the circuit only use components with a suitable electrical protection rating KLOVER srl declines all responsibility for injury to pers...

Page 15: ...of the pellets used The schedule indicated below may therefore vary Any problem affecting the stove caused by lack of cleaning will not be covered by the warranty Routine cleaning The stove requires...

Page 16: ...equipped with a fine mesh filter in order to prevent part of the ash from being spilled and thus damaging the cleaner itself Extraordinary cleaning To be performed at least every 30 days Perform routi...

Page 17: ...chamber sides and scrape the internal walls with a spatula removing any deposit Aspirare il deposito all interno utilizzando un aspiracenere idoneo e poi riposizionare il fondo ed il cassetto cenere...

Page 18: ...events whenever necessary It is important to check for any obstructions in the flue before switching the stove on following long periods of idleness If cleaning is not performed the operation of the s...

Page 19: ...n when at least one switch on off programme is active SCREW FEED the LED is on when the pellet loading gearmotor switches on FAN the LED is on when the hot air fan is active ON OFF the LED flashes dur...

Page 20: ...RAMMING Increases the value of the parameter 3 OFF WORK MODE Ignites or switches off the stove when pressed for 2 seconds ALARM BLOCK Releases alarm MENU Allows for accessing the selected menu MENU PR...

Page 21: ...ramme Stop Prog 1 Switch off time first weekly programme Mon Prog 1 Enable first programme Monday Tue Prog 1 Enable first programme Tuesday Wed Prog 1 Enable first programme Wednesday Thu Prog 1 Enabl...

Page 22: ...R Sub menu M2 1 ENABLE TIMER Allows for globally enabling and disabling all programmable thermostat functions Sub menu M2 2 DAILY PROGRAMME Allows for enabling disabling and setting the daily programm...

Page 23: ...amme Time OFF Mon Prog 3 Enable third programme Monday ON OFF Tue Prog 3 Enable third programme Tuesday ON OFF Wed Prog 3 Enable third programme Wednesday ON OFF Thu Prog 3 Enable third programme Thur...

Page 24: ...M6 FIRST LOADING Allows for performing pellet pre loading for 90 with the stove off and cold Start the function with button 2 and stop with button 3 It may be useful in case the stove is switched on...

Page 25: ...resistance to get hot enough before the loading of the pellet onto the crucible The appliance goes into FLAME STAND BY after the pre load phase starting to load the pellet onto the crucible at regula...

Page 26: ...LEANING for a pre defined duration see parameters table ATTENTION If you do not wish to control the stove with an ambient temperature it is advisable to set the SET TEMPERATURE value to MAN Manual If...

Page 27: ...e maximum safety temperature is reached inside the tank with resulting intervention of the safety thermostat with manual rearm In this case the stove must be restarted by rearming the safety thermosta...

Page 28: ...thus the stove will not switch on If the flue gets obstructed during normal operation the stove will burn all the pellets in the brazier before activating the DEPRESS FAILURE alarm the pellet tank go...

Page 29: ...se P1 SCREW FEED Seconds 0 1 4 0 0 8 Pr07 Screw feed gearmotor ON time in power 5 work phase P5 SCREW FEED Seconds 0 1 4 0 2 3 Pr08 Flue gas extraction speed in brazier cleaning phase EXTRACTOR CLEANI...

Page 30: ...nutes 2 120 2 Pr45 Power change delay POWER CHANGE Seconds 0 60 30 Pr46 Enabling of remote control ENABLE REMOTE On off On off OFF Pr47 Keypad block enabling KEYS BLOCK EN On off On off OFF Pr48 Autom...

Page 31: ...TOR T A ROOM THERMOSTAT CONNECTION FITTING TO ENSURE CORRECT OPERATION DO NOT REVERSE THE POLARITY OF THE WIRES RED BLUE PROGRAMMABLE THERMOSTAT BATTERY TYPE CR2032 3Volts PHASE NEUTRAL EARTH GROUND R...

Page 32: ...ries inside the device s electronic system and any other removable component if it is proved that their condition is due to a manufacturing defect rather than the effects of wear electric and electron...

Page 33: ......

Reviews: