PCB PARAMETERS 

THE PARAMETERS STORED ON THE PCB ARE ESSENTAL FOR THE CORRECT OPERATION OF THE 

STOVE. 

 

THE PARAMETERS SHOWN BELOW ARE STORED DURING THE STOVE TESTING PHASE DIRECTLY 

AT THE FACTORY. 

 

THESE PARAMETERS STEM FROM ACCURATE TESTS WITH VARIOUS TYPES OF PELLETS AND 

MUST NOT BE MODIFIED WITHOUT PRIOR AUTHORISATION FROM KLOVER srl, IN ORER TO AVOID 

JEOPARDISING THE STOVE'S OPERATION. 

THE  COMPANY  SHALL  NOT  BE  HELD  LIABLE  FOR  ANY  DAMAGES  CAUSED  BY  INCORRECT 

PARAMETER ENTRY. 

 

 

“Factory calibrations” (Menu M8 –

 1) 

(Firmware H02_250117)

 

 

 

Parameter 

Description 

Display text 

Unit of 

measurement 

Value field 

Database o1 

Pr01 

Ignition cycle maximum time 

IGNITION MINUTES 

Minutes 

 25 

20 

Pr02 

Start time 

START MINUTES 

Minutes 

 20 

Pr03 

Time interval between the two brazier 

cleaning operations 

CLEANING 

FREQUENCY 

Minutes 

10 

 255 

60 

Pr04 

Screw feed gearmotor ON time in ignition 

phase

SCREW FEED ON 

Seconds 

0.1 

 4.0 

1,0 

Pr05 

Screw feed gearmotor ON time in start 

phase 

SCREW FEED START 

Seconds 

0.1 

 4.0 

0,8 

Pr06 

Screw feed gearmotor ON time in power 1 

work phase 

P1 SCREW FEED 

Seconds 

0.1 

 4.0 

0,8 

Pr07 

Screw feed gearmotor ON time in power 5 

work phase 

P5 SCREW FEED 

Seconds 

0.1 

 4.0 

2,3 

Pr08 

Flue gas extraction speed in brazier 

cleaning phase 

EXTRACTOR 

CLEANING 

RPM 

700 

 2800 

2800 

Pr09 

Screw feed gearmotor ON time in 

cleaning phase 

CLEANING SCREW 

FEED 

Seconds 

0.0 

 4.0 

0,8 

Pr10 

Flue gas extractor switch-off threshold (in 

switch-off phase) 

THRESHOLD OFF 

°C 

50 

 180 

70 

Pr11 

Alarm delay 

ALARMS DELAY 

Seconds 

20 

 90 

30 

Pr12 

Brazier cleaning duration 

CLEANING DURATION 

Seconds 

 120 

60 

Pr13 

Flue gas minimum temperature for 

considering the stove on 

MINIMUM THRESHOLD 

°C 

35 

 180 

43 

Pr14 

Flue gas maximum temperature 

MAXIMUM 

THRESHOLD 

°C 

60 

 280 

250 

Pr15 

Flue gas temperature threshold for 

starting the heat exchangers 

FAN THRESHOLD 

°C 

50 

 210 

60 

Pr16 

Flue gas extraction speed in ignition 

phase 

EXTRACTOR ON 

RPM 

500 

 2800 

2300 

Pr17 

Flue gas extraction speed in start phase 

EXTRACTOR START 

RPM 

500 

 2800 

2000 

Pr18 

Flue gas extraction speed in power 1 work 

phase 

EXTRACTOR P1 

RPM 

500 

 2800 

1800 

Pr19 

Flue gas intake speed in power 5 work 

phase 

EXTRACTOR P5 

RPM 

500 

 2800 

2400 

Pr20 

Heat exchanger 1 motor speed in power 1 

work phase 

AIR P1 

Volt 

65 

 225 

190 

Pr21 

Heat exchanger 1 motor speed in power 5 

work phase  

AIR P5 

Volt 

65 

 225 

225 

 

 

 

 

 

 

Summary of Contents for DEA ECO 12

Page 1: ...STUFA A PELLET DEA ECO 12 INSTALLAZIONE USO E MANUNTENZIONE CONSIGLI UTILI ITALIANO FRAN AIS ENGLISH ESPA OL Cod CS IST SE12 Rev 1 3 S R L Main Revision 1 3 FPH_supplement 001...

Page 2: ...9 FLUE AND CONNECTION TO THE LATTER STACK 10 ELECTRICAL CONNECTION 13 CLEANING AND MAINTENANCE 14 PRECAUTIONS BEFORE CLEANING 14 ROUTINE CLEANING 14 EXTRAORDINARY CLEANING 15 CLEANING THE CERAMIC GLA...

Page 3: ...or proper installation basic maintenance and control points which must be performed regularly furthermore it contains practical advice for obtaining maximum performance from the stove with minimum fue...

Page 4: ...for which it was designed Do not use different fuels to those recommended Do not use liquid fuels The device especially its external surfaces becomes very hot to the touch during operation handle it...

Page 5: ...s operational limits Regularly perform all maintenance activities Authorise expert and competent people to use the stove Failure to comply with the requirements of this guide shall automatically void...

Page 6: ...E GUIDE ONE WARRANTY COUPON ONE POWER SUPPLY CABLE This manual is an integral part of the machine if the stove is sold it must be handed down to the new owner AMBIENT TEMPERATURE SENSOR PELLET TANK SE...

Page 7: ...6 ENGLISH Connections data sheet S 80 mm M FLUE GAS OUTLET A 33 mm AIR EXTRACTION DEVICE E SWITCH WITH ELECTRIC CABLE CONNECTION REAR VIEW...

Page 8: ...imum draught Pa 12 1 12 1 Pellet tank capacity Kg 27 Pellet min max hourly consumption Kg h 2 81 0 51 Operating autonomy at minimum maximum output h 10 53 Flue pipe diameter mm 80 Nominal voltage V 22...

Page 9: ...conformity to international standards such as EN14961 2 DIN 51731 and O NORM M7135 are indicated on the packaging The packages are intact since pellets tend to absorb humidity Humidity not only reduce...

Page 10: ...measurements to be observed when positioning the stove in relation to the walls REAR WALL SIDE WALL SIDE WALL 50 cm 50 cm 10 cm Any shelves or false ceilings mounted above the stove must be at least 5...

Page 11: ...imney is essential to the efficient operation of a Klover appliance The chimney should be designed and constructed according to these instructions and relevant regulations including Building Regulatio...

Page 12: ...and initial vertical rise The flue system should run as vertically as possible as any deviations off the vertical can adversely affect the draw 45 is the maximum off vertical angle than may be used N...

Page 13: ...deciding whether a particular chimney design will provide sufficient draught The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulati...

Page 14: ...rom parts subject to high temperatures During the final wiring of the circuit only use components with a suitable electrical protection rating KLOVER srl declines all responsibility for injury to pers...

Page 15: ...of the pellets used The schedule indicated below may therefore vary Any problem affecting the stove caused by lack of cleaning will not be covered by the warranty Routine cleaning The stove requires...

Page 16: ...equipped with a fine mesh filter in order to prevent part of the ash from being spilled and thus damaging the cleaner itself Extraordinary cleaning To be performed at least every 30 days Perform routi...

Page 17: ...chamber sides and scrape the internal walls with a spatula removing any deposit Aspirare il deposito all interno utilizzando un aspiracenere idoneo e poi riposizionare il fondo ed il cassetto cenere...

Page 18: ...events whenever necessary It is important to check for any obstructions in the flue before switching the stove on following long periods of idleness If cleaning is not performed the operation of the s...

Page 19: ...n when at least one switch on off programme is active SCREW FEED the LED is on when the pellet loading gearmotor switches on FAN the LED is on when the hot air fan is active ON OFF the LED flashes dur...

Page 20: ...RAMMING Increases the value of the parameter 3 OFF WORK MODE Ignites or switches off the stove when pressed for 2 seconds ALARM BLOCK Releases alarm MENU Allows for accessing the selected menu MENU PR...

Page 21: ...ramme Stop Prog 1 Switch off time first weekly programme Mon Prog 1 Enable first programme Monday Tue Prog 1 Enable first programme Tuesday Wed Prog 1 Enable first programme Wednesday Thu Prog 1 Enabl...

Page 22: ...R Sub menu M2 1 ENABLE TIMER Allows for globally enabling and disabling all programmable thermostat functions Sub menu M2 2 DAILY PROGRAMME Allows for enabling disabling and setting the daily programm...

Page 23: ...amme Time OFF Mon Prog 3 Enable third programme Monday ON OFF Tue Prog 3 Enable third programme Tuesday ON OFF Wed Prog 3 Enable third programme Wednesday ON OFF Thu Prog 3 Enable third programme Thur...

Page 24: ...M6 FIRST LOADING Allows for performing pellet pre loading for 90 with the stove off and cold Start the function with button 2 and stop with button 3 It may be useful in case the stove is switched on...

Page 25: ...resistance to get hot enough before the loading of the pellet onto the crucible The appliance goes into FLAME STAND BY after the pre load phase starting to load the pellet onto the crucible at regula...

Page 26: ...LEANING for a pre defined duration see parameters table ATTENTION If you do not wish to control the stove with an ambient temperature it is advisable to set the SET TEMPERATURE value to MAN Manual If...

Page 27: ...e maximum safety temperature is reached inside the tank with resulting intervention of the safety thermostat with manual rearm In this case the stove must be restarted by rearming the safety thermosta...

Page 28: ...thus the stove will not switch on If the flue gets obstructed during normal operation the stove will burn all the pellets in the brazier before activating the DEPRESS FAILURE alarm the pellet tank go...

Page 29: ...se P1 SCREW FEED Seconds 0 1 4 0 0 8 Pr07 Screw feed gearmotor ON time in power 5 work phase P5 SCREW FEED Seconds 0 1 4 0 2 3 Pr08 Flue gas extraction speed in brazier cleaning phase EXTRACTOR CLEANI...

Page 30: ...nutes 2 120 2 Pr45 Power change delay POWER CHANGE Seconds 0 60 30 Pr46 Enabling of remote control ENABLE REMOTE On off On off OFF Pr47 Keypad block enabling KEYS BLOCK EN On off On off OFF Pr48 Autom...

Page 31: ...TOR T A ROOM THERMOSTAT CONNECTION FITTING TO ENSURE CORRECT OPERATION DO NOT REVERSE THE POLARITY OF THE WIRES RED BLUE PROGRAMMABLE THERMOSTAT BATTERY TYPE CR2032 3Volts PHASE NEUTRAL EARTH GROUND R...

Page 32: ...ries inside the device s electronic system and any other removable component if it is proved that their condition is due to a manufacturing defect rather than the effects of wear electric and electron...

Page 33: ......

Reviews: