Transport and Storage 

WP-3-D/Ex,  WP-5-D/Ex,  WP-7-D/Ex,  WP-8-D/Ex  and  WP-9-D/Ex, are placed in cardboard,  
on the surface of which is written their weight.  
Whereas the big fans:  WP-10-D/Ex,  WP-11-D/Ex  are simply placed on pallets. During the 
loading and transport the packing should not be thrown or knocked down. Do not put any load  
on top of the package.   
The packages should not be placed one on top of another and 

protect them

 against atmosphe- 

ric factors and damage. 

The devices should be

 transported in packages to the place of storage 

and installing. 
 
The fans have to be stored in rooms of following properties: 

– 

without dustiness,  gases and vapours and other substances of aggressive properties and  
without chemical exhalations that could have destructive effect on the insulation elements,  
constructional elements of the motor and the fan,  

– 

maximum relative humidity should not exceed 80% at the tempe20

C, 

– 

the ambient temperature should range from 

–20

C to +40

C, 

– 

there should not be any vibrations. 

 
 

12.

 

Terms of warranty 

The period of warranty for the purchased device is indicated in the “Card of Warranty”.  
The warranty does not comprise: 

 

●  mechanical damage and dysfunctions caused by User, 

 

 

●  damages of the fan caused by lack of the current protections  –  i.e. short-circuit- and 

overload protections, 

 

 

●  device failures caused during use which was in contradiction with the purpose of ope-

rational use and the present Use and Maintenance Manual, 

 

 

●  damages being effected during improper transport, storage or incorrect maintenance. 

 

Infringement of the S

ection 3 “Reservations of Producer” of the Use and Maintenance 

Manual and especially modifications 

undertaken by

 

User on one’s own shall cause the 

loss of warranty validity. 

 

 

Summary of Contents for WP-10-D/Ex

Page 1: ...1 18 10 2016 Ex proof roof fans WP D Ex Use and Maintenance Manual Explosion proof roof fans WP D Ex ATEX mark II 2 G c Ex e ll T3...

Page 2: ...servations of Producer 5 4 Technical Data 5 5 Structure and Function 7 6 Assembly and Start up 7 7 Operational Use 9 8 Troubleshooting Guide 9 9 Maintenance 10 10 Occupational Health and Safety 10 11...

Page 3: ...vailable on the market of electrical equipment designed within certain voltage limits Journal of Laws EC L96 of 29 03 2014 2014 34 EC ATEX Directive of the European Parliament and of the Council of Fe...

Page 4: ...pheres are possible to occur It can be applied in zones 1 2 G the appliance is marked on the Ex classification board II 2 G c Ex e II T3 Marking of the operational conditions of the device group categ...

Page 5: ...er rotations should not exceed the nominal rotations I Producer is not responsible for wounds injuries body laceration experienced by User or personnel during the improper operational use 4 Technical...

Page 6: ...6 5 480 130 500 WP 5 D Ex 915 525 60 160 160 194 6 6 5 480 140 WP 7 D Ex 965 570 60 200 160 194 6 6 5 510 155 WP 8 D Ex 990 600 60 200 200 224 8 8 5 535 155 WP 9 D Ex 1030 665 60 200 200 224 8 8 5 580...

Page 7: ...to lead the electrostatic charges away On the motor housing is located a clamp to fasten the protective cable Additionally on the motor housing is a connection box of the power supply The hemi spheri...

Page 8: ...l connections are performed correctly b Examine the connection correctness of the electrical connections phases sequence c Check the correctness of the connection between the motor and the PE protecti...

Page 9: ...nces of the incorrect use damage of the bearings damages caused by corrosion loss in balance of the rotating elements vibrations deformations damages caused by friction Risks which can occur due to im...

Page 10: ...r supply system Examption from this is a test to carried out on the running fan for example vibration measuring In this case especially follow the rules of Occupational Health and Safety wait until th...

Page 11: ...ld have destructive effect on the insulation elements constructional elements of the motor and the fan maximum relative humidity should not exceed 80 at the temperature 20 C the ambient temperature sh...

Page 12: ...12 Ex proof roof fans WP D Ex 18 10 2016...

Page 13: ...WP 3 D Ex II 2G EExe II T3 3000 0 37 1 0 18 2 BESEL WP 5 D Ex II 2G EExe II T3 3000 0 55 1 4 12 0 BESEL WP 7 D Ex II 2G EExe II T3 3000 1 1 2 4 7 2 BESEL WP 8 D Ex II 2G EExe II T3 3000 1 5 3 5 10 0 I...

Page 14: ...9 03 2014 The device has been constructed and produced on the basis of subsequent standards PN EN ISO 12100 2012 Safety of machinery Basic concepts general principles for design Risk assessment and ri...

Page 15: ...15 18 10 2016 Ex proof roof fans WP D Ex NOTES...

Page 16: ...58 629 64 80 fax 058 629 64 19 e mail klimawent klimawent com pl www klimawent com pl 808W49 WP 3 D Ex 18 10 2016 EN 808W50 WP 5 D Ex 18 10 2016 EN 808W51 WP 7 D Ex 18 10 2016 EN 808W52 WP 8 D Ex 18 1...

Reviews: