background image

 

 5 

 

 

 

 

08.11.2019

                                       

dust separator

  WE-5,5/D

 

 

 

 

 

Fig. No.3  

–  WE-5,5/D  –  Maintenance   

6.

 

Assembly and Start-up 

WE-5,5/D dust separator is designed for use in a closed room (indoor application). It should 
be placed stably on an even floor surface.  Important is the free access of the cooling air cir-
culation  and that there is enough place  to replace the bag filter and the waste bag.  It is re-
commended  to install  a silencer  at the outlet,  as this significantly  reduces the noise level.   
ZE-WE-5,5/D control unit  ought to  be installed in a place that is convenient for User.  Addi- 
tionally, it is important to provide  3x230V, 50Hz  or 3x400V, 50Hz power supply, depending  
on the supply versions. The control unit provides possibility of controlling the device function  
from the switchgear  or from the external closable contact.  Additionally, a non-potential con- 
tact is guided onto the X4 terminal strip (see Connection Diagrams).  The non-potential con- 
tact is closed during the work of the fan. 

The device  should be connected  to the power supply system  

by User on one’s own, 

by selecting the appropriate sort and section of the supply cables and an appropriate  
protection from the short-circuit- and overload effects  

–  according to the being valid 

regulations and with reference to the local conditions. 

 

 

 

   Any activities  pertaining  to  connection to the power supply system  

have to be performed exclusively by an authorised person with testified qualifications  
and in compliance with the being in force valid regulations

.

 

 
Prior to the device start-up examine subsequent aspects: 

 

the voltage value of the supply installation, 

 

connection correctness of the protective cable, 

 

connection correctness of the electrical installation and selection of the protections, 

 

mounting and tightness of the bag filter, waste bag and housing covers. 

 

 

Summary of Contents for WE-5,5/D

Page 1: ... klimawent com pl www klimawent com pl 800O96 WE 5 5 D 08 11 2019 EN Contents 1 Introductory Remarks 2 2 Application 2 3 Reservations of Producer 3 4 Technical Data 3 5 Structure and Function 4 6 Assembly and Start up 5 7 Operational Use 10 8 Troubleshooting Guide 12 9 Maintenance 13 10 Occupational Health and Safety 13 11 Transport and Storage 14 12 Terms of warranty 14 13 Sample of the Declarati...

Page 2: ...en 125W and 500 kW Journal of Laws L No 90 of 06 04 2011 Additionally the appliance meets following harmonized standard EN ISO 12100 2012 Safety of machinery Basic concepts general principles for design Risk assessment and risk reduction EN 60204 1 2018 12 Safety of machinery Electrical equipment of machines Part 1 General requirements EN ISO 13857 2010 Safety of machinery Safe distances to preven...

Page 3: ...nd bag filter from mechanical damage F The appliance is not designed for conveying the air containing following contaminants viscous or humid as they could deposite within the appliance especially clog the filters fine impurities of dispersion below 10 microns aggressive compounds G Manufacturer is not responsible for wounds injuries body laceration experienced by User or personnel during the impr...

Page 4: ...ht dust fractions accumulate on the internal sur surface of the filtration bag from there they are periodically shaken struck by means of a vi bration mechanism down into the paper bag The motor of the vibration mechanism is operated automatically at the moment when the fan is switched off It is important to connect the suction connection of the dust separator with the processing ma chine where th...

Page 5: ...act Additionally a non potential con tact is guided onto the X4 terminal strip see Connection Diagrams The non potential con tact is closed during the work of the fan The device should be connected to the power supply system by User on one s own by selecting the appropriate sort and section of the supply cables and an appropriate protection from the short circuit and overload effects according to ...

Page 6: ...6 dust separator WE 5 5 D 08 11 2019 Version of the 3x230V power supply Fig No 4 WE 5 5 D Main connection diagram 3x230V ...

Page 7: ...7 08 11 2019 dust separator WE 5 5 D Fig No 5 Connection of the external elements ...

Page 8: ...8 dust separator WE 5 5 D 08 11 2019 Version of 3x400V power supply Fig No 6 WE 5 5 D Main Connection Diagram 3x400V ...

Page 9: ...9 08 11 2019 dust separator WE 5 5 D Fig No 7 Connection of external elements ...

Page 10: ...E 5 5 D 08 11 2019 7 Operational Use The control functions with the device work proceeds by means of the ZE 5 5 D control unit Housing of the control unit is illustrated in the Fig below Fig No 8 Case of the control unit ...

Page 11: ... lamp built in the S3 button indicates one of the three alarm states The dust separator function is controlled by the ZE WE 5 5 D control unit SWITCHING ON THE POWER SUPPLY Turn the S1 switch into position ON this is indicated by the white lamp H1 HOW TO START THE FAN Turn the S2 switch into position ON the fan starts drawing the impurities through the ex traction ducting The fan function is indic...

Page 12: ...bearings damages being caused by corrosion loss in balance of the rotary elements vibrations deformations damages being caused by friction Hazards that may occur due to inappropriate use damages and other defects caused by rupture of the impeller breaking of the shaft fatigue rupture of the material fire and explosion caused by sparks The construction of the device provides its operational use wit...

Page 13: ...he power supply by means of the S1 switch Make sure that there would be possible a hazard of accidental device starting during the maintenance e g not controlled using of the above mentioned switch If necessary put a notification CAUTION DEVICE UNDER REPAIR DO NOT SWITCH ON THE POWER SUPPLY or similar on the control unit Wait until the motors of the separator drives stop rotating Before the mainte...

Page 14: ...e would not get detached from the surface or obliterated During the storing take into account following rules the device must be stored in the transport package and protected from weather conditions the place area of storage should be dry and without dust storage temperature 10ºC up to 40ºC 12 Terms of warranty The period of warranty for the purchased device is indicated in the Card of Warranty Th...

Page 15: ... 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Par liament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric in put power between 125W and 500 kW Journal of Laws L No 90 of 06 04 2011 The appliance meets following harmonized standard EN ISO 12100 2012 Safety of machinery Basic concepts general pr...

Page 16: ...16 dust separator WE 5 5 D 08 11 2019 NOTES ...

Reviews: