dust separator

  WE-5,5/D

 

 

 

Function of the control devices  

(markings are compatible with the Connection Diagrams)

 

S1 

– 

general disconnector 

– switches off and disconnects the separator from the power 

sup-ply system. 

Q1M 

– 

motor protective switch 

– protects the motor from damage  due to the blocked start-up, 

overload, short-circuit and incomplete-phase run. 

Q2M 

– 

motor protective switch 

– protects the motor from damage  due to the blocked start-up, 

overload, short-circuit and incomplete-phase run.  Provides possibility of switching 

ON

 

and 

OFF

 of the device from the power supply system  (from the main circuit as well as 

from the control unit). 

F1 

– 

overcurrent switch 

– protects from short-circuit occurring within the control system. 

K1M 

– 

contactor 

– start-up of the fan. 

K2M 

– 

contactor 

– start-up of the fan. 

PLC 

– 

controller 

– control over the device function. 

S1 

– 

illuminated switch “

ON

/

OFF

” – applies the supply onto the control system. When it is 

switched into position 

ON

 

– the supply application is signalised by light in the switch. 

S2 

– 

triple-position switch 

– switches on the switchgear or the remote control. 

S3 

– 

illuminated green pushbutton “

RESET

” – carries out the reset after the removal of the 

reasons of the alarm. 

 

Description of the control lamps on the front panel

 

(markings are compatible with the Connection Diagrams)

 

H1 

– 

white lamp 

– power supply 

ON

 

H2 

– 

green lamp 

– fan 

ON

 

S3H3 

– 

red lamp 

– built in the 

S3

 button 

– indicates one of the three alarm states 

The dust separator function is controlled by the ZE-WE-5,5/D control unit. 
 

SWITCHING  ON  THE POWER  SUPPLY

 

Turn the 

S1

 

switch into position “

ON

” – this is indicated by the white lamp 

H1

 

HOW  TO  START  THE  FAN 

Turn the 

S2

 

switch into position “

ON

” – the fan starts drawing the impurities through the ex- 

traction ducting.  The fan function is indicated by the green lamp 

H2

 

WHEN  THE  WASTE  BAG  IS  FILLED  UP

 

The fill-up state is signalised by the red lamp 

H3

 

ALARM

”, simultaneously the fan is being 

switched off.  After 10 seconds (for the period of 20 seconds) the shaking vibrator operates 
to remove the fine dusts from the bag filter, into the waste bag. 
 
After that, open the door in the lower segment, lift the two side levers and slide out the troll- 
ley with the waste bag. Replace the bag for a new,  protect it and close tightly the door. To  
restart the fan press the 

S3

 

button “

RESET

”. 

After each fan stop (when the 

S2

 

switch is set into position “

OFF

”), automatically starts the 

fine dust shaking of the bag filter  and the vibrator is running (during the normal function of  
the device) 

– after 10 seconds the vibrator switches on  and runs for 20 seconds.  The fan 

should be restarted by setting the 

S2 

switch into “

ON

”. 

 

HOW  TO  STOP  THE  DUST  SEPARATOR

 

To switch off the device,  set the 

S2

 

switch  into position “

OFF

”,  and  subsequently the 

S1

 

switch into position “

OFF

”. 

 

REMOTE  CONTROL  (OPTION) 

Remote control is provided as a possibility of operating the device.  As optional equipment,  
(for external controlling) is applied an outer panel. 

Summary of Contents for WE-5,5/D

Page 1: ... klimawent com pl www klimawent com pl 800O96 WE 5 5 D 08 11 2019 EN Contents 1 Introductory Remarks 2 2 Application 2 3 Reservations of Producer 3 4 Technical Data 3 5 Structure and Function 4 6 Assembly and Start up 5 7 Operational Use 10 8 Troubleshooting Guide 12 9 Maintenance 13 10 Occupational Health and Safety 13 11 Transport and Storage 14 12 Terms of warranty 14 13 Sample of the Declarati...

Page 2: ...en 125W and 500 kW Journal of Laws L No 90 of 06 04 2011 Additionally the appliance meets following harmonized standard EN ISO 12100 2012 Safety of machinery Basic concepts general principles for design Risk assessment and risk reduction EN 60204 1 2018 12 Safety of machinery Electrical equipment of machines Part 1 General requirements EN ISO 13857 2010 Safety of machinery Safe distances to preven...

Page 3: ...nd bag filter from mechanical damage F The appliance is not designed for conveying the air containing following contaminants viscous or humid as they could deposite within the appliance especially clog the filters fine impurities of dispersion below 10 microns aggressive compounds G Manufacturer is not responsible for wounds injuries body laceration experienced by User or personnel during the impr...

Page 4: ...ht dust fractions accumulate on the internal sur surface of the filtration bag from there they are periodically shaken struck by means of a vi bration mechanism down into the paper bag The motor of the vibration mechanism is operated automatically at the moment when the fan is switched off It is important to connect the suction connection of the dust separator with the processing ma chine where th...

Page 5: ...act Additionally a non potential con tact is guided onto the X4 terminal strip see Connection Diagrams The non potential con tact is closed during the work of the fan The device should be connected to the power supply system by User on one s own by selecting the appropriate sort and section of the supply cables and an appropriate protection from the short circuit and overload effects according to ...

Page 6: ...6 dust separator WE 5 5 D 08 11 2019 Version of the 3x230V power supply Fig No 4 WE 5 5 D Main connection diagram 3x230V ...

Page 7: ...7 08 11 2019 dust separator WE 5 5 D Fig No 5 Connection of the external elements ...

Page 8: ...8 dust separator WE 5 5 D 08 11 2019 Version of 3x400V power supply Fig No 6 WE 5 5 D Main Connection Diagram 3x400V ...

Page 9: ...9 08 11 2019 dust separator WE 5 5 D Fig No 7 Connection of external elements ...

Page 10: ...E 5 5 D 08 11 2019 7 Operational Use The control functions with the device work proceeds by means of the ZE 5 5 D control unit Housing of the control unit is illustrated in the Fig below Fig No 8 Case of the control unit ...

Page 11: ... lamp built in the S3 button indicates one of the three alarm states The dust separator function is controlled by the ZE WE 5 5 D control unit SWITCHING ON THE POWER SUPPLY Turn the S1 switch into position ON this is indicated by the white lamp H1 HOW TO START THE FAN Turn the S2 switch into position ON the fan starts drawing the impurities through the ex traction ducting The fan function is indic...

Page 12: ...bearings damages being caused by corrosion loss in balance of the rotary elements vibrations deformations damages being caused by friction Hazards that may occur due to inappropriate use damages and other defects caused by rupture of the impeller breaking of the shaft fatigue rupture of the material fire and explosion caused by sparks The construction of the device provides its operational use wit...

Page 13: ...he power supply by means of the S1 switch Make sure that there would be possible a hazard of accidental device starting during the maintenance e g not controlled using of the above mentioned switch If necessary put a notification CAUTION DEVICE UNDER REPAIR DO NOT SWITCH ON THE POWER SUPPLY or similar on the control unit Wait until the motors of the separator drives stop rotating Before the mainte...

Page 14: ...e would not get detached from the surface or obliterated During the storing take into account following rules the device must be stored in the transport package and protected from weather conditions the place area of storage should be dry and without dust storage temperature 10ºC up to 40ºC 12 Terms of warranty The period of warranty for the purchased device is indicated in the Card of Warranty Th...

Page 15: ... 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Par liament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric in put power between 125W and 500 kW Journal of Laws L No 90 of 06 04 2011 The appliance meets following harmonized standard EN ISO 12100 2012 Safety of machinery Basic concepts general pr...

Page 16: ...16 dust separator WE 5 5 D 08 11 2019 NOTES ...

Reviews: