Klimawent SMART-SN User Manual Download Page 9

Klimawent

 – the warranty of highest quality at attractive price 

 

 

 

18.06.2020

 

Roof fans SMART-SN

 

9 of 15

 

 

Table 4 Characteristic dimensions of SMART-SN type fans from 3000 rpm 

Type of fan 

A [mm] 

B [mm] 

ØC [mm] 

ØD [mm] 

ØE [mm] 

N [pcs] 

SMART-160-SN 

590 

220 

545 

160 

194 

SMART-200-SN 

200 

224 

SMART-250-SN 

250 

274 

SMART-315-SN 

315 

344 

 

Table 5 Sound-absorbing roof bases TPD-N and TPDC-N 

Type 

Part no. 

Name 

Application 

 

TPD-N 

843P40 

TPD-160-N 

SMART-160/3000-SN 

843P41

 

TPD-200-N 

SMART-200/3000, 1500, 1000-SN 

843P42

 

TPD-250-N 

SMART-250/3000, 1500, 1000-SN 

843P43

 

TPD-315-N 

SMART-315/3000, 1500, 1000-SN 

843P44

 

TPD-400-N 

SMART-400/1500, 1000, 750-SN 

843P45

 

TPD-500-N 

SMART-500/1000, 750-SN 

843P46

 

TPD-630-N 

SMART-630/1000, 750-SN 

843P47

 

TPD-710-N 

SMART-710/1000, 750-SN 

 

TPDC-N 

843P50 

TPDC-160-N

 

SMART-160/3000-SN 

843P51

 

TPDC-200-N

 

SMART-200/3000, 1500, 1000-SN 

843P52

 

TPDC-250-N

 

SMART-250/3000, 1500, 1000-SN 

843P53

 

TPDC-315-N

 

SMART-315/3000, 1500, 1000-SN 

843P54

 

TPDC-400-N

 

SMART-400/1500, 1000, 750-SN 

843P55

 

TPDC-500-N

 

SMART-500/1000, 750-SN 

843P56

 

TPDC-630-N

 

SMART-630/1000, 750-SN 

843P57

 

TPDC-710-N

 

SMART-710/1000, 750-SN 

 

Table 6 Additional equipment 

 

Type 

Part no. 

Description 

 

Service switch

 

IS 

843W30

 

It is used to disconnect the single-phase or three-phase 

electric motors power supply circuit with rated current up 

to 

16 A

. Locking the knob in the 

0

 or 

OFF

 position. 

 

Motor starter

 

RS 

816R... 

(depending 

on the 

power)

 

It is used to directly switch on and off single- and three-

phase motors. It performs the function of protection 

against overload and undervoltage and signals the on 

state. 

Summary of Contents for SMART-SN

Page 1: ...AL USE 13 TROUBLESHOOTING GUIDE 13 MAINTENANCE AND RECYCLING INSTRUCTIONS 13 OHS MANUAL 14 TRANSPORT AND STORAGE 14 TERMS OF WARRANTY 14 EXAMPLE OF EC DECLARATION OF CONFORMITY 15 18 06 2020 Manufactu...

Page 2: ...f 6 4 2011 page 8 Regulation of the Polish Minister of Economy of 21 October 2008 on requirements for machines Journal of Laws No 199 of 2008 item 1228 Also meets the requirements of the following har...

Page 3: ...vacuum Pa Synchronous rotation rpm Motor rate kW Supply voltage V Hz Mass kg SMART 160 3000 SN 813W30 2 300 740 3000 0 55 3 400V 50Hz 16 SMART 200 3000 SN 813W33 3 550 800 0 55 16 SMART 250 3000 SN 81...

Page 4: ...SMART 1500 SN roof fans 100 200 300 400 500 600 700 800 900 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Static pressure Pa Flow rate m3 h SMART 160 3000 SN SMART 200 3000 SN SMART 250 3000 SN...

Page 5: ...cs of SMART 1000 SN roof fans part 2 of 2 200 225 250 275 300 325 350 375 400 0 500 1000 1500 2000 2500 3000 3500 Static pressure Pa Flow rate m3 h SMART 200 1000 SN SMART 250 1000 SN 0 100 200 300 40...

Page 6: ...0 1000 630 1000 710 1000 400 750 500 750 630 750 710 750 1m 79 79 80 80 74 75 80 85 67 65 68 73 78 84 87 63 69 77 81 5m 70 69 70 70 64 66 70 75 56 56 59 62 68 74 77 55 59 67 71 10m 62 62 63 63 57 58 6...

Page 7: ...cy point 3 Efficiency category 2 Measurement category 1 Overall efficiency Product information Table 4 Energy performance of roof fans SMART SN not supplied with the fan see chapter no 9 MAINTENANCE A...

Page 8: ...ss G 2 5 Each SMART SN fan is equipped with an inlet with a round flange with holes which allows the fan to be mounted with threaded fasteners see below Picture 2 and Table 3 The top side of the fans...

Page 9: ...N SMART 630 1000 750 SN 843P47 TPD 710 N SMART 710 1000 750 SN TPDC N 843P50 TPDC 160 N SMART 160 3000 SN 843P51 TPDC 200 N SMART 200 3000 1500 1000 SN 843P52 TPDC 250 N SMART 250 3000 1500 1000 SN 8...

Page 10: ...g roof bases of appropriate sizes and TK type channel silencers The use of a sound absorbing roof base reduces the noise reaching the room by approx 12 18dB A SMART SN fans should be transported on a...

Page 11: ...er supply remove the fan cover to gain access to the motor junction box After completing the connections replace the fan cover Diagram 1 Star motor connection Y Diagram 2 Triangle motor connection SER...

Page 12: ...in the immediate vicinity 3 Set the motor protection to 1 1 electric current at the fan duty point with a limit not exceeding It 1 1 In where In is the rated motor current Control and commissioning B...

Page 13: ...bject rotor damage replace the impeller with a new one poor efficiency wrong rotor rotation direction change the impeller rotation direction by changing the phase order loud fan operation destruction...

Page 14: ...operating assembling electrically connecting commissioning and service repairs comply with safety regulations standards and generally accepted technical rules Due to the presence of sharp edges and c...

Page 15: ...ment and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy related products recast Official Journal L 285 of 31 10 2009 page 10 Commission...

Reviews: