Specific disclaimers 

 

Roof fans 

SMART-SN

 cannot be used to flowing the flammable mixtures with air in the form of gas, vapor, 

mist or dust, which may create an 

explosive atmosphere

 

Roof fans 

SMART-SN

 cannot be used to flowing the air containing 

sticky

 impurities that can settle on the 

impeller and inside. 

 

Roof fans 

SMART-SN

 cannot be used to flowing the air containing 

caustic

 impurities that may have an 

adverse effect on the device. 

 

Roof fans 

SMART-SN

 cannot be used to flowing the air with a 

temperature higher than +60°C

 

When using 

SMART-SN

 fans with frequency converters (inverters), the maximum rotor speed may NOT 

be higher than the nominal speed of the motor of the given fan type. 

 

TECHNICAL DATA 

Table 1 Technical data of roof fans SMART-SN 

Type of fan 

Part no. 

Maximum 

volume flow  

[m

3

/h] 

Maximum 

vacuum 

[Pa] 

Synchronous 

rotation 

[rpm] 

Motor 

rate 

[kW] 

Supply 

voltage 

[V, Hz] 

Mass 

[kg] 

SMART-

160

/3000-SN 

813W30

 

2 300

 

740 

3000 

0,55 

3×400V, 

50Hz

 

16 

SMART-

200

/3000-SN 

813W33 

3 550 

800 

0,55 

16 

SMART-

250

/3000-SN 

813W36 

4 750 

735 

0,55 

15 

SMART-

315

/3000-SN 

813W40 

4 710 

440 

0,37 

16 

SMART-

200

/1500-SN 

813W32 

3 300 

690 

1500 

0,55 

57 

SMART-

250

/1500-SN 

813W35 

4 600 

690 

1,1 

64 

SMART-

315

/1500-SN 

813W39 

9 400 

790 

1,5 

66 

SMART-

400

/1500-SN 

813W41 

12 500 

860 

2,2 

75 

SMART-

200

/1000-SN 

813W31 

2 540 

370 

1000 

0,37 

58 

SMART-

250

/1000-SN 

813W34 

3 000 

350 

0,37 

57 

SMART-

315

/1000-SN 

813W38 

4 800 

260 

0,55 

56 

SMART-

400

/1000-SN 

813W42 

8 300 

380 

0,75 

64 

SMART-

500

/1000-SN 

813W44 

15 000 

520 

1,5 

89 

SMART-

630

/1000-SN 

813W46 

23 300 

540 

3,0 

150 

SMART-

710

/1000-SN 

813W48 

36 000 

790 

5,5 

175 

SMART-

400

/750-SN 

813W43 

6 000 

200 

750 

0,37 

62 

SMART-

500

/750-SN 

813W45 

11 800 

240 

1,1 

81 

SMART-

630

/750-SN 

813W47 

18 500 

350 

1,5 

135 

SMART-

710

/750-SN 

813W49 

29 000 

450 

2,2 

152 

 

Note:

 Ingress protection code of electrical motor – 

IP 54

 

It  is  recommended  to  use  TPD-N  or  TPDC-N  sound-absorbing  roof  bases  and  TK  channel 
silencers to reduce noise levels. 

 

 

Summary of Contents for SMART-SN

Page 1: ...AL USE 13 TROUBLESHOOTING GUIDE 13 MAINTENANCE AND RECYCLING INSTRUCTIONS 13 OHS MANUAL 14 TRANSPORT AND STORAGE 14 TERMS OF WARRANTY 14 EXAMPLE OF EC DECLARATION OF CONFORMITY 15 18 06 2020 Manufactu...

Page 2: ...f 6 4 2011 page 8 Regulation of the Polish Minister of Economy of 21 October 2008 on requirements for machines Journal of Laws No 199 of 2008 item 1228 Also meets the requirements of the following har...

Page 3: ...vacuum Pa Synchronous rotation rpm Motor rate kW Supply voltage V Hz Mass kg SMART 160 3000 SN 813W30 2 300 740 3000 0 55 3 400V 50Hz 16 SMART 200 3000 SN 813W33 3 550 800 0 55 16 SMART 250 3000 SN 81...

Page 4: ...SMART 1500 SN roof fans 100 200 300 400 500 600 700 800 900 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Static pressure Pa Flow rate m3 h SMART 160 3000 SN SMART 200 3000 SN SMART 250 3000 SN...

Page 5: ...cs of SMART 1000 SN roof fans part 2 of 2 200 225 250 275 300 325 350 375 400 0 500 1000 1500 2000 2500 3000 3500 Static pressure Pa Flow rate m3 h SMART 200 1000 SN SMART 250 1000 SN 0 100 200 300 40...

Page 6: ...0 1000 630 1000 710 1000 400 750 500 750 630 750 710 750 1m 79 79 80 80 74 75 80 85 67 65 68 73 78 84 87 63 69 77 81 5m 70 69 70 70 64 66 70 75 56 56 59 62 68 74 77 55 59 67 71 10m 62 62 63 63 57 58 6...

Page 7: ...cy point 3 Efficiency category 2 Measurement category 1 Overall efficiency Product information Table 4 Energy performance of roof fans SMART SN not supplied with the fan see chapter no 9 MAINTENANCE A...

Page 8: ...ss G 2 5 Each SMART SN fan is equipped with an inlet with a round flange with holes which allows the fan to be mounted with threaded fasteners see below Picture 2 and Table 3 The top side of the fans...

Page 9: ...N SMART 630 1000 750 SN 843P47 TPD 710 N SMART 710 1000 750 SN TPDC N 843P50 TPDC 160 N SMART 160 3000 SN 843P51 TPDC 200 N SMART 200 3000 1500 1000 SN 843P52 TPDC 250 N SMART 250 3000 1500 1000 SN 8...

Page 10: ...g roof bases of appropriate sizes and TK type channel silencers The use of a sound absorbing roof base reduces the noise reaching the room by approx 12 18dB A SMART SN fans should be transported on a...

Page 11: ...er supply remove the fan cover to gain access to the motor junction box After completing the connections replace the fan cover Diagram 1 Star motor connection Y Diagram 2 Triangle motor connection SER...

Page 12: ...in the immediate vicinity 3 Set the motor protection to 1 1 electric current at the fan duty point with a limit not exceeding It 1 1 In where In is the rated motor current Control and commissioning B...

Page 13: ...bject rotor damage replace the impeller with a new one poor efficiency wrong rotor rotation direction change the impeller rotation direction by changing the phase order loud fan operation destruction...

Page 14: ...operating assembling electrically connecting commissioning and service repairs comply with safety regulations standards and generally accepted technical rules Due to the presence of sharp edges and c...

Page 15: ...ment and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy related products recast Official Journal L 285 of 31 10 2009 page 10 Commission...

Reviews: