Roof fans SMART-SN

 

18.06.2020

 

 

Type 

Part no. 

Description 

 

Motor circuit breaker

 

WS 

843W... 

(depending 

on the 

power)

 

It is used to directly switch on and off single- and three-

phase motors. It has short-circuit and overload protection. 

It protects the motor against damage as a result of blocked 

starting, overload, short circuit and lack of one phase in 

three-phase networks. 

 

Inverter 

FA 

816F... 

(depending 

on the 

power)

 

It is used to regulate the rotational speed of fans with 

three-phase electric motors. It is possible to program a 

specific application proposed by the customer. 

 

INSTALLATION AND COMMISSIONING 

 

Installation 

The fans should be mounted on plinths equipped with appropriate roof bases. To reduce the sound pressure 

(noise), it is recommended to use 

TPD-N

 or 

TPDC-N

 type sound-absorbing roof bases of appropriate sizes and 

TK

  type  channel  silencers. The  use  of  a sound-absorbing  roof  base  reduces  the  noise  reaching  the  room  by 

approx. 

12-18dB(A)

.  

SMART-SN

 fans should be transported on a pallet or using transport handles located under the cover on the 

fan motor plate. 

 

The fan must not be transported using the motor's transport eye! Use only the eyes mounted 

on the fan motor plate.

 

 

Picture 4 TPD-N sound-absorbing roof base 

 

Picture 5 TPDC-N sound-absorbing roof base 

 

Table 7 Characteristic dimensions of TPD-N and TPDC-N attenuating roof bases 

Type 

Part no. 

D [mm]  A [mm]  H [mm] 

Type 

Part no.  D [mm] A [mm] B [mm] H [mm] 

TPDC-160-N 

843P50 

160 

430 

625 

TPD-160-N 

843P40 

160 

430 

630 

625 

TPDC-200-N 

843P51 

200 

TPD-200-N 

843P41 

200 

TPDC-250-N 

843P52 

250 

530 

950 

TPD-250-N 

843P42 

250 

530 

730 

950 

TPDC-315-N 

843P53 

315 

TPD-315-N 

843P43 

315 

TPDC-400-N 

843P54 

400 

790 

1200 

TPD-400-N 

843P44 

400 

790 

990 

1200 

TPDC-500-N 

843P55 

500 

TPD-500-N 

843P45 

500 

TPDC-630-N 

843P56 

630 

890 

1200 

TPD-630-N 

843P46 

630 

890 

1090  1200 

TPDC-710-N 

843P57 

710 

TPD-710-N 

843P47 

710 

Summary of Contents for SMART-SN

Page 1: ...AL USE 13 TROUBLESHOOTING GUIDE 13 MAINTENANCE AND RECYCLING INSTRUCTIONS 13 OHS MANUAL 14 TRANSPORT AND STORAGE 14 TERMS OF WARRANTY 14 EXAMPLE OF EC DECLARATION OF CONFORMITY 15 18 06 2020 Manufactu...

Page 2: ...f 6 4 2011 page 8 Regulation of the Polish Minister of Economy of 21 October 2008 on requirements for machines Journal of Laws No 199 of 2008 item 1228 Also meets the requirements of the following har...

Page 3: ...vacuum Pa Synchronous rotation rpm Motor rate kW Supply voltage V Hz Mass kg SMART 160 3000 SN 813W30 2 300 740 3000 0 55 3 400V 50Hz 16 SMART 200 3000 SN 813W33 3 550 800 0 55 16 SMART 250 3000 SN 81...

Page 4: ...SMART 1500 SN roof fans 100 200 300 400 500 600 700 800 900 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Static pressure Pa Flow rate m3 h SMART 160 3000 SN SMART 200 3000 SN SMART 250 3000 SN...

Page 5: ...cs of SMART 1000 SN roof fans part 2 of 2 200 225 250 275 300 325 350 375 400 0 500 1000 1500 2000 2500 3000 3500 Static pressure Pa Flow rate m3 h SMART 200 1000 SN SMART 250 1000 SN 0 100 200 300 40...

Page 6: ...0 1000 630 1000 710 1000 400 750 500 750 630 750 710 750 1m 79 79 80 80 74 75 80 85 67 65 68 73 78 84 87 63 69 77 81 5m 70 69 70 70 64 66 70 75 56 56 59 62 68 74 77 55 59 67 71 10m 62 62 63 63 57 58 6...

Page 7: ...cy point 3 Efficiency category 2 Measurement category 1 Overall efficiency Product information Table 4 Energy performance of roof fans SMART SN not supplied with the fan see chapter no 9 MAINTENANCE A...

Page 8: ...ss G 2 5 Each SMART SN fan is equipped with an inlet with a round flange with holes which allows the fan to be mounted with threaded fasteners see below Picture 2 and Table 3 The top side of the fans...

Page 9: ...N SMART 630 1000 750 SN 843P47 TPD 710 N SMART 710 1000 750 SN TPDC N 843P50 TPDC 160 N SMART 160 3000 SN 843P51 TPDC 200 N SMART 200 3000 1500 1000 SN 843P52 TPDC 250 N SMART 250 3000 1500 1000 SN 8...

Page 10: ...g roof bases of appropriate sizes and TK type channel silencers The use of a sound absorbing roof base reduces the noise reaching the room by approx 12 18dB A SMART SN fans should be transported on a...

Page 11: ...er supply remove the fan cover to gain access to the motor junction box After completing the connections replace the fan cover Diagram 1 Star motor connection Y Diagram 2 Triangle motor connection SER...

Page 12: ...in the immediate vicinity 3 Set the motor protection to 1 1 electric current at the fan duty point with a limit not exceeding It 1 1 In where In is the rated motor current Control and commissioning B...

Page 13: ...bject rotor damage replace the impeller with a new one poor efficiency wrong rotor rotation direction change the impeller rotation direction by changing the phase order loud fan operation destruction...

Page 14: ...operating assembling electrically connecting commissioning and service repairs comply with safety regulations standards and generally accepted technical rules Due to the presence of sharp edges and c...

Page 15: ...ment and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy related products recast Official Journal L 285 of 31 10 2009 page 10 Commission...

Reviews: