Klimawent ALAN-U/C-8-HD-N Use And Maintenance Manual Download Page 4

Klimawent

 – the warranty of highest quality at attractive price 

 

 

 

4 z 8 

Reel Exhaust Extractor

 ALAN-U/C-HD-N

 

23.05.2019 

 

Section and duct length (suitable to the fan outlet diameter) should be selected to meet the minimum volume flow 
measured at the suction terminal is not lower than the value specified in Section 4 

– Technical Data – Recommen-

ded volume flow.  To control the extraction fan function apply electrical equipment specified in Section FANS of 
the KLIMAWENT S.A. catalogue. 
 
As standard, the hose reel is equipped with: 

● 

band brake 

– to slow down the rotations of the reel during recoiling, 

● 

ratchet gear (locking pawl) 

– to block the hose assembly in the requested convenient position. 

Reel extractors  ALAN-U/C-HD-N are adapted for coiling h

oses of Ø200 mm diameter and length 8m and 12m 

respectively. 

 

 

Table No.4  

Extractor type 

Dimensions 

[mm] 

1

.

 

framework 

 

D1 

D2 

2

.

 

hose reel 

ALAN-U/C-8-HD-N 

775  1000 

455 

550 

820 

965 

3

.

 

reel cover 

ALAN-U/C-12-HD-N 

1200  1465 

455 

550 

820 

965 

4

.

 

hose guiding spiral 

 

 

 

 

 

 

 

5

.

 

connection fitting piece 

 

 

 

 

 

 

 

6

.

 

spring mechanism 

 

 

 

 

 

 

 

7

.

 

band brake 

Fig. No.2  

–  ALAN-U/C-HD-N  –  Description and dimensions of the exhaust reel 

 

 

ASSEMBLY  AND  STARTUP 

ALAN-U/C-HD-N-type extractor is being supplied in following assemblies: 

● 

hose reel 

– along with the frame structure (including the spring mechanism and the brake), 

● 

hose assembly 

– lengths 8 or 12 metres;  diameters Ø100, Ø125, Ø150 or Ø200 mm. The hose assembly 

consists of:  hose, hose clamps, rubber clamp covers for the hose clamps, 

 

● 

rubber stopper, 

● 

nozzle. 

 
 

Additionally, 

extraction fans

 of various types i.e. can be delivered upon separate order: 

 

● 

built-on fans type 

FA/HD

 

– installed directly to the extractor reel; 

● 

flange-type fans 

WPA-E-N

  or  roof fans 

WPA-D-N

 

– mentioned in Section 4; 

 

as well as ventilation conduits (flexible or rigid), wall brackets, roof bases and similar ventilation accessories. 

 

INSTALLING OF THE FAN TYPE FA/HD

The fan has to be installed to the left wall of the framework.  Following steps of installing: 

1

.

 

put a sealing ring on the outlet connection of the reel extractor 

2

.

 

in the bottom part, screw up 2 mounting bolts to fasten the solid bush to the left wall;  put the fan support and 
screw it up with these bolts, along with the solid bush and the framework wall; 

3

.

 

put the fan (with the motor) onto the connection in such a way 

– that the hangers holes (in the upper part of 

the fan) are matching the holes in the left framework wall, and the hole in the support is suitable to the hole in 
the fan housing.  The fan inlet opening ought to be installed evenly  onto the sealing ring. 

4

.

 

screw up the fan with the extractor to the hangers (by means of 4 bolts) and additionally to the support (1 bolt); 
altogether 5 bolts M8x20. 

 

FASTENING  OF  THE  HOSE ASSEMBLY  TO THE REEL 

1

.

 

Turn by hand the hose reel to the left (when viewing onto the spring housing): 

 

– 

at least 3 rotations for the hose assembly of 8 metres length 

 

– 

at least 4 rotations for the hose assembly of 12 metres length (until the tensioning springs get stretched) 

 

 

Summary of Contents for ALAN-U/C-8-HD-N

Page 1: ...NCTION 3 ASSEMBLY AND STARTUP 4 OPERATIONAL USE 6 TROUBLESHOOTING GUIDE 7 MAINTENANCE 7 OCCUPATIONAL HEALTH AND SAFETY 7 TRANSPORT AND STORAGE 7 TERMS OF WARRANTY 7 DECLARATION OF CONFORMITY 8 23 05 2...

Page 2: ...ide the premises The extractor can be installed under the ceiling or to the walls columns by means of wall brackets The system works with following fans manufactured by KLIMAWENT S A built on fans FA...

Page 3: ...TRUCTURE AND FUNCTION The Reel Exhaust Extractor consists of a winding reel installed in a framework adapted for mounting under the ceiling or on a wall Onto the reel is wound a hose with a nozzle Noz...

Page 4: ...The hose assembly consists of hose hose clamps rubber clamp covers for the hose clamps rubber stopper nozzle Additionally extraction fans of various types i e can be delivered upon separate order buil...

Page 5: ...STALL THE EXTRACTOR AT THE WORKPLACE Reel Exhaust Extractor can be mounted under the ceiling or to the wall column by means of wall brackets It is important that the reel axle is levelled horizontally...

Page 6: ...ipe 4 To wind up the hose pull it gently the spring mechanism shall recoil the hose onto the reel Pay attention that the hose is being wound evenly on the reel 5 Having recoiled the hose switch off th...

Page 7: ...ust Extractor are admissible after getting acquainted with the contents of the present User s Manual Connection to the power system ought to be carried out according to the enclosed connection diagram...

Page 8: ...ENT S A hereby declares that the product Reel Exhaust Extractor type model ALAN U C HD N serial number ___________________ year of production ___________________ Meets the requirements of the European...

Reviews: