Klimawent ALAN-U/C-8-HD-N Use And Maintenance Manual Download Page 2

Klimawent

 – the warranty of highest quality at attractive price 

 

 

 

2 z 8 

Reel Exhaust Extractor

 ALAN-U/C-HD-N

 

23.05.2019 

 

 

INTRODUCTION 

The purpose of the present Use and Maintenance Manual is to supply User with directions within the range of 
application, assembly, start-up and operational use of the 

ALAN-U/C-HD-N

 Reel Exhaust Extractor. 

 

Prior to assembly at the place of operation and use, it is important to get thoroughly acquain-
ted with the contents of the present instruction. 

 

With regard to continuity of work carried on improvement of our products, we reserve for 
ourselves  the  revision  possibility  of  the  draft  and  technological  changes  improving  their 
functional features and safety.

 

Construction of 

ALAN-U/C-HD-N

 meets the requirements of the current state of technology as well as the safety 

and health assurances included in: 

2006/42/EC  Directive

 of  the  European  Parliament  and  of  the  Council  of  the  17  May,  2006  on  machinery, 

amending the 95/16/EC Directive (recast) / Official Journal EC L157 of the 09.06.2006, page 24); 
 
Additionally, it is in accordance with the subsequent harmonised standards: 

EN ISO-12100:2012

  

   

Safety of machinery 

– General principles of design – Assessment and reduction of hazard 

 

 

PURPOSE 

ALAN-U/C-HD-N

 Reel Exhaust Extractors with a spring drive are designed for effective removal of noxious and 

hazardous chemical compounds emitted in exhaust gases of vehicles during diagnostics, adjustment, and engine 
tests and similar. They eliminate health hazards and risk of life of the operating personnel, provide clean air at the 
workplace,  thereby providing more safety and comfort.  They are used in bus depots, garages and service stations 
for trucks, building construction vehicles, special vehicles.   
Along with the optimum air extraction and simple use 

– they provide a discharge of the whole exhaust volume 

outside the premises. 
The extractor can be installed under the ceiling or to the walls / columns by means of wall brackets. The system 
works with following fans manufactured by KLIMAWENT S.A.: 

– 

built-on fans 

FA

 

– installed directly at the exhaust reel, 

– 

flange-type fans 

WPA-E-N

 

– installed independently on a separate bracket, 

– 

roof fans 

WPA-D-N

 

 

RESERVATIONS  OF  MANUFACTURER 

 

Manufacturer  accepts  no  liability  for  any  consequences  following  from  the  operational  use  that  is  in 
contradiction to the purpose of application. 

 

Operational  use  with cooperation  with  an inefficiently functioning  extraction fan, as this  would result  in 
overheating and damage of the exhaust hose. 

 

Protect the exhaust hose  from mechanical damage  and  pollution  with oils and solid lubricating grease. 

 

Maintenance and any repair can be executed exclusively by an authorised person. 

 

During  the  use,  the  vehicle  engine  can  work  at  maximum  rotations  for  not  longer  time  than  60 
seconds

 

During hose winding

 

– observe that the hose is distributing on the reel evenly, regularly to avoid clenching. 

 

Prior to installing 

– check the load carrying capacity of the ceiling / wall, in a place where the unit shall be 

installed;  unsure setting of mounting bolts could result in uncontrolled device detachment, its damage 
and risk to the operator / people in the vicinity. 

 

Installing of any additional elements  that are not belonging  to the normal device structure (or accessory 
set) is not acceptable. 

 

Do not introduce any structural or constructional modifications on the device on 

one’s own. 

 

Manufacturer is not responsible for body lacerations, injuries, wounds 

– experienced by operator due to 

careless use or negligence. 

 

 

TECHNICAL  DATA 

Table No.1 

Extractor type 

Equipped with a 
shut-off damper 

Maximum 

torque 

Maximum length of the 

exhaust hose 

Diameter of the 

exhaust hose 

Weight 

 

 

[Nm] 

[m] 

[mm] 

[kg] 

ALAN-U/C-8-HD-N 

no 

50 

200 

44,5 

ALAN-U/C-12-HD-N 

no 

100 

12 

200 

68 

CAUTION:

  

1

upon selection of the extractor size 

– contact KLIMAWENT S.A. 

2

weight of the extractor is specified without the installed hose 

 

 

Summary of Contents for ALAN-U/C-8-HD-N

Page 1: ...NCTION 3 ASSEMBLY AND STARTUP 4 OPERATIONAL USE 6 TROUBLESHOOTING GUIDE 7 MAINTENANCE 7 OCCUPATIONAL HEALTH AND SAFETY 7 TRANSPORT AND STORAGE 7 TERMS OF WARRANTY 7 DECLARATION OF CONFORMITY 8 23 05 2...

Page 2: ...ide the premises The extractor can be installed under the ceiling or to the walls columns by means of wall brackets The system works with following fans manufactured by KLIMAWENT S A built on fans FA...

Page 3: ...TRUCTURE AND FUNCTION The Reel Exhaust Extractor consists of a winding reel installed in a framework adapted for mounting under the ceiling or on a wall Onto the reel is wound a hose with a nozzle Noz...

Page 4: ...The hose assembly consists of hose hose clamps rubber clamp covers for the hose clamps rubber stopper nozzle Additionally extraction fans of various types i e can be delivered upon separate order buil...

Page 5: ...STALL THE EXTRACTOR AT THE WORKPLACE Reel Exhaust Extractor can be mounted under the ceiling or to the wall column by means of wall brackets It is important that the reel axle is levelled horizontally...

Page 6: ...ipe 4 To wind up the hose pull it gently the spring mechanism shall recoil the hose onto the reel Pay attention that the hose is being wound evenly on the reel 5 Having recoiled the hose switch off th...

Page 7: ...ust Extractor are admissible after getting acquainted with the contents of the present User s Manual Connection to the power system ought to be carried out according to the enclosed connection diagram...

Page 8: ...ENT S A hereby declares that the product Reel Exhaust Extractor type model ALAN U C HD N serial number ___________________ year of production ___________________ Meets the requirements of the European...