Klimawent
– the warranty of highest quality at attractive price
8 of 12
Ozone generator KILLVIR-48
25.01.2021
Note 1 Warning regarding ozonation
! WARNING
A.
People and animals must not be in the ozonated room, plants should also be removed
from it.
B.
Ozone room should be properly sealed so that ozone does not leak outside to adjacent
rooms or the environment.
C.
If the room is ventilated, turn off its ventilation.
D.
People should not stay in rooms adjacent to ozone plants, into which some ozone could
penetrate. It is necessary to exclude the possibility of exposure to increased
concentrations of ozone by outsiders.
E.
All ozone sensitive materials should be removed from the room.
F.
Do not use ozone in the environment of flammable gases or explosives!
G.
It is forbidden to smoke, work with open fire, work with tools that generate a flame or
sparks, work with oils and greases, or leave objects contaminated with oil or grease in
an ozonated room!
H.
After the ozonation treatment is completed, the room should be aired for at least 15
minutes; it is best not to enter it earlier than 1 hour after the end of ozonation.
STORAGE
The device should be stored according to the following rules:
A.
The device should be stored in a transport packaging that protects against external factors.
B.
The storage place should be dry and dust-free and at a temperature between -10ºC and + 40ºC.
TERMS OF WARRANTY
The warranty period is specified in the device
Warranty Card
. The warranty does not cover:
mechanical and electrical damages of the device caused by the user,
damage resulting from improper use or failure to comply with the operating instructions,
damage resulting from improper transport, storage, or improper maintenance.
! CAUTION
Non-compliance with point 3 “MANUFACTURER'S DISCLAIMER” of this manual,
especially the unauthorized modification of the device or its improper use will void the
warranty!
RESIDUAL RISK INFORMATION
! CAUTION
Ozone treatment of rooms must always be performed by qualified personnel secured with
appropriate personal protective equipment.
Types of risk and security measure
Ozone [O
3
]
During operation of the
KILLVIR-48
generator, 48 g of volatile ozone are produced each hour. Ozone is harmful
to human health during the operation of the device, as well as in the form of ozone treatment residues.