background image

18

 (3)

Fix the accessory cable with the Interconnection cable block.

 (4)

 

Confirm the fixing of the accessory cable is ok.

(2)

Take off the block for Interconnection cable, then put the core of the power wire to the terminal and 

     fix it according to the diagrams pasted to indoor and outdoor unit separately.

 (5)

Fix the cover for Interconnection cable on.

(1)

Take off the cover for Interconnection cable of outdoor unit.

Diagram for installation of Interconnection cable

 ( please see the pasted diagram instruction on the body first)

Cooling & Heating

Cooling Only 

Connetting 
indoor unit

Connetting 
power

Connetting 
outdoor unit

Connetting 
indoor unit

Connetting 
power

Indoor Unit

3 N

1 2

L

Connetting 
outdoor unit

Indoor Unit

N

1

L

Outdoor Unit

N

1

L

N

L

Outdoor Unit

3 N

1 2

L

N

L

1 N

1 2 3 N

Cooling & Heating

1 2 3 N

 Cooling Only

1 N

Connetting outdoor unit

Connetting indoor unit

1 L

N

1 L

N

Indoor Unit

Outdoor Unit

09K,12K, 18K indoor interconnection cable sketch map

24K indoor and outdoor  interconnection cable sketch map

09K,12K, 18K outdoor  interconnection cable sketch map

Split frequency conversion air conditioner interconnection cable
 means(Heating and cooling was as same as Cooling

 

Installation Instructions

Interconnection Cable

 Circuit Diagram

 Cooling Only

Cooling & Heating

Note: Some models are designed without the conneting terminal in indoor unit,please subject 
          to the connetion diagram of the product.

Summary of Contents for SPLIT AIR-CONDITIONER

Page 1: ...ome this Owner s Manual should be read carefully be fore using your air conditioner Afterre ading st ore it in a safe place P lease refer to the manual for questions on useo rin the event that any irr...

Page 2: ...s any button when the flashes If you dont press any button within 10 seconds the remote controller is pre set as Heat Pump automatically the symbol will flash from Cool and HEAT alternatively heating...

Page 3: ...us injury etc SLEEP FAN TIMER SWING ON OFF MODE MED LO SWING AUTO HI DRY FAN HEAT COOL FEEL SLEEP TIMER ON OFF Use correct power supply in accordance with the rating plate requirement Otherwise seriou...

Page 4: ...ntake Air Intake Air Outlet Louver Vertical Adjustment Louver Horizontal Adjustment Electrostatic Filter optional Charcoal Filter optional Air Filter Remote Controller Front Panel Emergency Panel Disp...

Page 5: ...t when the remote controller is out of work If there is any difference between the sketch map and the substantiality please subject to the substantiality R unIndic ator It is on during operation S lee...

Page 6: ...ortable SLEEP Used to start and stop operation Used to adjust airflow direction Used to select TIMER operation Signal Transmitting Window Transmits signals to the system Setting Display Transmitting d...

Page 7: ...or each time the batteries are replaced as they are discharged the remote control mades a short Auto Test all the symbols can be displayed are shown on the screen and keep 2 seconds then the symbol wi...

Page 8: ...m air conditioner aim the remote control to the signal receptor The remote control will operate the air conditioner at a distance of up to 23 ft when pointing at signal receptor of indoor unit Remote...

Page 9: ...possible with the button or the button Press the MODE select button Move the MODE to the FEEL position 1 2 Operates by selecting automatically the operation mode HEAT DRY FAN COOL depending on the ro...

Page 10: ...nds SLEEP operation is switched from Normal SLEEP to SLEEP alternatively Comfortable Used to set or cancel sleep operation This function is invalid in fan and dehumidify mode This function is invalid...

Page 11: ...usty environment Stop the appliance and remove the air filter 1 Open the front panel 2 Press the handle of the filter gently from the front 3 Grasp the handle and slide out the filter soft cloth to cl...

Page 12: ...5 minutes later In HEATING operation the appliance will defrost de ice automatically to raise efficiency This procedure usually lasts 2 10 minutes During defrosting fans stop operation After defrostin...

Page 13: ...e power supply and connect back 2 3 seconds later Changing mode during operation 3 minutes will delay This odor may come from another source such as furniture cigarette etc which is sucked in the unit...

Page 14: ...hould be over 6 in should be over 79 in should be over 12 in Installation must be performed in accordance with the national wiring standards by authorized personnel only Above figure is only a simple...

Page 15: ...re is no obstacle near the air outlet and air can be easily blown to every corner Where piping and wall hole can be easily arranged Keep the required space from the unit to the ceiling and wall accord...

Page 16: ...a sleeve through the wall hole to keep the wall tidy and clean Drill a hole on the wall The hole should tilt a little downward toward outside Decide the position of hole for piping according to the 2...

Page 17: ...lation tube Power cord 1 for heat pump Power cord Defrost cable for heat pump Drain hose prepared by user A Insert the pipe fixer to the slot B Press to hook the pipe fixer onto the base Base Base Bas...

Page 18: ...ble thickness is as specified in the power source specification See the cable specification table below 3 Check the wires and make sure that they are all tightly fastened after cable connection 4 Be s...

Page 19: ...ct the condensate water Just install the drain port and rubber washer to the chassis of the outdoor unit then connect a drain hose to the port as the right figure shown The air which contains moisture...

Page 20: ...tdoor unit Connetting indoor unit Connetting power Indoor Unit 3 N 1 2 L Connetting outdoor unit Indoor Unit N 1 L Outdoor Unit N 1 L N L Outdoor Unit 3 N 1 2 L N L 1 N 1 2 3N Cooling Heating 12 3N Co...

Page 21: ...o a double pole switching device with contact separation of at least 1 8 in placed in an accessible position even after installation NOTE NOTE Test Running Connect to the power source check if the fun...

Page 22: ...5 594 4972 Fax 305 675 2212 www klimaire com sales klimaire com 2190 NW 89 Place Doral FL 33172 USA The Klimaire logo is a registered Trademark of Klimaire Products inc Copyright 2010 Klimaire Product...

Reviews: