background image

FIRE DAMPERS

356

357

Design changes reserved

FIRE DAMPER FDC25

357

FIRE CLASSIFICATION

357

SELECTION DIAGRAM

358

ORDERING KEY

358

DAMPER MODELS

359

FDC25-M cylindrical fire damper with electrical actuator

359

FDC25-R cylindrical fire damper with manual mechanism

359

FDC25-E cylindrical fire damper with solenoid actuator

360

INSTALLATION OPTIONS

361

Installation in a rigid wall (mortar based)

361

Installation in a flexible wall (mortar based)

361

Installation in ceiling (mortar based)

362

Installation in a rigid wall (mortarless)

362

Installation in a flexible wall (mortarless)

363

Installation in ceiling (mortarless)

363

Suspension for mortarless installation

364

ACCESSORIES

363

Fexible connectors

364

Cover grille

364

OPERATING INSTRUCTIONS

365

FDC25-R cylindrical fire damper with manual mechanism 

365

FDC25-E cylindrical fire damper with solenoid actuator

365

Electrical characteristics and wiring scheme for a Belimo actuator

366

FIRE DAMPER CONTROL

367

TABLE OF CONTENTS

Summary of Contents for FD25-E

Page 1: ...355 www klimaoprema hr FDC25 FIRE DAMPER 7 S4 v 2 9 en...

Page 2: ...ased 361 Installation in a flexible wall mortar based 361 Installation in ceiling mortar based 362 Installation in a rigid wall mortarless 362 Installation in a flexible wall mortarless 363 Installati...

Page 3: ...with greater fire resistance can also be used Fire damper should be installed according instal lation manual which can be found within this document Table 1 Dimensions FIRE DAMPER FDC25 Standard diam...

Page 4: ...sm type R manual mechanism E230 solenoid actuator AC230V E24 solenoid actuator AC 24V M230 electric actuator AC230V M24 electric actuator AC DC 24V Options s electric limit switches indicating damper...

Page 5: ...er blade 2 electric actuator Belimo BLF 3 thermo electric tripping device 72 C 4 intumescent strip 5 Options M230 electric actuator AC 230V M24 electric actuator AC DC 24V FDC25 R cylindrical fire dam...

Page 6: ...zed steel but on demand can be made from Galvanized steel and powder coated Stainless steel Stainless steel and powder coated Fire damper for areas with potentially explosive atmospheres are also avai...

Page 7: ...FDC25 Wall according to table 1 Installation steps Recommended wall opening for fire damper installation is 160mm but openings from 80 200 mm can also be used Insert fire damper into wall and secure o...

Page 8: ...mper blade mobility preform an opening and closing test 3 4 Fire damper FDC25 Wall according to table 1 Installation in a rigid wall mortarless 1 2 3 4 Installation steps Recommended ceiling opening f...

Page 9: ...ing test 3 4 Fire damper FDC25 Wall according to table 1 Installation material Fire damper FDC25 Mineral wool 140kg m3 Fire protection coating HILTI weichschott system Installation steps Recommended c...

Page 10: ...ble connectors are being installed very important is to install extension peace if necessary see table 2 ACCESSORIES Suspension for mortarless installation Suspension systems are required for the dry...

Page 11: ...e supplied with one or two limit switches switches can also be fitted later DAMPER OPEN DAMPER CLOSED Fire damper is shipped with closed damper blade Fire damper with manual actuating mechanism is ope...

Page 12: ...not move the damper into closed position after power failure ther moelectric fuse switch for checking for proper functioning handle for manual opening Belimo BLF24 T i BF24 T supply via safety isolati...

Page 13: ...per Level Digital field controller K FC24 Digital field controller to control and monitor up to 4 motorized fire dampers and 4 smoke detectors Communication Modbus RTU RS 485 The safety function of th...

Reviews:

Related manuals for FD25-E