Kleinwaechter EFM 023 BGT Manual Download Page 3

 

General information on electrostatics 

Calibration.......................................................................................................................................................................... 14 

Warning Notices .............................................................................................................................................................. 15 

Ad-On facilities :

 ................................................................................................................................................................ 15 

Audit Kit 1 - CPM ............................................................................................................................................................. 15 

Additional Scope of Delivery ................................................................................................................................. 15 

Audit Kit 2 - Complete ................................................................................................................................................... 16 

Additional Scope of Delivery ................................................................................................................................. 16 

 

General information on electrostatics 

Nowadays ESD

1

 is a problem at many workstations, because modern microelectronics

2

 is easily 

destroyed by the sequels of ESD. Other branches of industry like e.g. telecommunications-, plas-
tics-, and explosive material industry are also heavily affected by ESD. 

ESD causes losses of time as well as high financial losses and can endanger the human health. 
Charges of over 10000 Volts can emerge on people, clothes, materials and equipment.  Devices 
that are sensitive to electrostatics can be damaged by electrostatic discharges of less than  
100 Volts. Charges of 3000 Volts and more can cause sparks. In endangered areas that can cause 
explosions. 

Origin of electrostatic charge 

Triboelectricity

3

 is caused by attrition of different materials. Electrons are transferred from one 

material to the other. As electrons are charged negative the material that releases electrons is 
charged positive. The material admitting electrons is charged negative. There are different ways 
to avoid or to discharge electrostatic charges. But to find an effective and reasonable solution 
first of all the emergence, amount and polarity of the charge have to be found. Our devices are 
suitable for that purpose and for the supervision of favored charge. 

Product description 

The unit is housed into an EMV plastic enclosure. The influence electrode is star shaped. In front 
of it in a small distance apart a rotating grounded modulation propeller with the same shape as 
the electrode is located. The influence electrode is enclosed by a ring electrode system that is 
used as mechanical shield for the propeller wheel and the sensor plate. A 2×12 digit alpha-
numeric LC display is located at the front of the device. 

The device has an integrated micro computer with the following functions: 

 

Conversion of the measured field intensity over the adjusted measurement distance to 
the charge in Volts 

 

one button operation 

 

permanent supervision of the battery voltage with automatic shut-down 

 

charge plate mode

4

 

 

pos. and neg. Maximum Value memory

5

 

 

1

 electrostatic discharge 

2

 integrated circuits 

3

 Greek: tribeia = friction 

4

 with optional CPS kit 

Summary of Contents for EFM 023 BGT

Page 1: ...MANUAL EFM 023 BGT System Prof Dr Ing Hans Kleinw chter Walking Test with EFM 023 and UAC 110...

Page 2: ...nt ranges 7 E Field Meter Measurement 7 Max Value 7 Analog Output 7 Changing the measurement distance 8 Spacers 8 Display 9 Battery Monitoring 9 Grounding 9 Maintenance 9 Battery Replacement 10 Zero P...

Page 3: ...aterial that releases electrons is charged positive The material admitting electrons is charged negative There are different ways to avoid or to discharge electrostatic charges But to find an effectiv...

Page 4: ...esolution 10Bit Battery 9V alkaline or NiMH battery Operating time Approx 10h with alkaline battery Measuring range Voltmeter Distance Measuring range Max resolution 1cm 0 10kV 1V 2cm 0 20kV 2V 5cm 0...

Page 5: ...M023 In the middle of the left side here is the output socket for the analog output 1 Cover cap 5 Spacer 2 Modulator system 6 Zero point trimmer 3 Button function on 7 Alphanumeric LCD display 4 Groun...

Page 6: ...briefly to change to a new distance or to CPS mode wait approx 2s to select the displayed function Aus Press function on 2 times in quick succession Initiation By pressing the function on button on t...

Page 7: ...Field Meter Mode In this Mode it s possible to select the following ranges 20KV m 200kV m or 1MV m To change the ranges press the function on key briefly The range changed as following In this Mode t...

Page 8: ...m the plate behind the modulator blade The plate is located 6 4mm in front of the devices front plane After switching the device off and on always 2cm distance are selected Without the manual E Field...

Page 9: ...further damage Attention Use only Rechargeable 9V NiMH Battery or an 9V Alkaline Battery Batteries have to be charged outside the device in a suited battery charger Please pay attention to the manufac...

Page 10: ...of the device The guarantee expires if the device was opened Batteries and accumulators are not allowed in the household waste Every consumer must by law dispose of all batteries and accumulators at...

Page 11: ...oltage measuring head MK 023 you get a high impedance volt meter with an impedance off 1016 Ohm That takes to measure static voltage at isolated conductive parts up to 4kV Select distance 1cm that wil...

Page 12: ...Alphanumeric LCD display 4 Metal spacers 5 Measuring head MK023 Specifications Voltage measuring head Dimensions L x W x H Approx 80mm x 40mm x 37mm Weight Approx 80g Measuring voltage Approx 4kV Han...

Page 13: ...Switch on EFM 023 and wait until Dist 2cm displayed Connect CPS socket to ground connect Hand electrode with Silicon cable to the measure input screw theVoltage measuring head 5 on the spacers replace...

Page 14: ...Start the walking test by pressing the Start button in the software End the walking test by pressing the Stop button By pressing the Reset button max Values will be erased Scope of Delivery The basic...

Page 15: ...s on the modulator system must be avoided The use of the device in power plants or comparable areas is prohibited The device can not measure alternating fields 1Hz Ad On facilities Audit Kit 1 CPM Ord...

Page 16: ...A Ohm Meter TOM 100 with Temperature and humidity Sensor TF 100 Additional Scope of Delivery Plate Electrode 75mm x 150mm 20pF HV Converter 1 100V LC TERA Ohm Meter TOM 100 TOM Surface Measure Electro...

Reviews: