X3-KIT
Installation and Operation Manual
PG 28/40
REV: BETA (4/25/2019)
8.8.
Air Compressor - Installation
8.8.1.
Route 1/4” air tubing connected to
front of Air Tank across back of firewall, or above chassis, as desired
and secure using supplied zip ties. There should be 12 inches of excess tubing sticking out of
Driver’s
side to manipulate and connect to Air Compressor
WARNING
: Route plastic tubing distant from heat sources; tubing should never exceed 150 deg F while
in use, as tubing can rupture under 150 psi compressed air and cause harm, or injury.
Figure 19
–
Air Tubing Route from Air Compressor to Air Tank
8.8.2.
On a bench, install Air Compressor Leader Hose Adapter Bracket (X3-102) on to back of Compressor and
zip tie hose, as shown below. Use a razor blade, or scissors to cut Rubber Grommet in half. Apply
adequate Kleinn Air Horn Juice to end of Leader Hose when installing Air Fitting (F8).
CAUTION:
It is not recommended to attempt to remove Leader Hose from Compressor and create a
single run of 1/4” Air Tu
bing. Leader Hose removal may permanently damage threads in Compressor.
Figure 20
–
Installing Air Compressor Leader Hose Adapter Bracket
Route Air Tubing
across Firewall, or
above Chassis
Excess tubing here
- trim to length
F8
H14 (2)
H17
X3-102
Apply Air
Horn Juice
H17
H14