RESISTANCE MEASUREMENTS
1. Insert the RED test lead into the VΩ jack
5
and the BLACK
test lead into the COM jack
4
, and rotate the Function selector
switch
2
to the Continuity/Resistance/Diode test
setting.
NOTE:
The meter will default to continuity testing in this mode.
Press the 'SEL' button
9
once to enter Resistance testing mode.
The Resistance icon will appear on the display.
2. Stop the power to the circuit.
3. Measure resistance by connecting the test leads to the circuit.
The meter will auto-range to display the measurement in the
most appropriate range.
NOTE:
When in the Resistance setting and the test leads are open
(not connected across a resistor), or when a failed resistor is under
test, the display will indicate OL. This is normal.
DO NOT attempt to measure resistance on a live circuit.
CONTINUITY
1. Insert the RED test lead into the VΩ jack
5
and the BLACK
test lead into the COM jack
4
, and rotate the Function selector
switch
2
to the Continuity/Resistance/Diode test
setting.
NOTE:
The meter will default to continuity testing in this mode.
Ensure that the Continuity testing icon is visible on the display. If
not, press the 'SEL' button
9
repeatedly until the icon is shown.
2. Stop the power to the circuit.
3. Test for continuity by connecting the conductor or circuit with test
leads. If resistance is measured at less than 50 Ω, an audible signal
will sound and the display will show a resistance value indicating
continuity. If the circuit is open, the display will show '
OL
'.
DO NOT attempt to measure continuity on a live circuit.