11
OPERATING INSTRUCTIONS
AC/DC VOLTAGE (LESS THAN 1,000 V)
1. Insert the RED test lead into the VΩ jack
5
and the BLACK
test lead into the COM jack
4
, and rotate the Function selector
switch
2
to the AC/DC voltage
V
setting. The meter defaults
to AC measurement. To measure DC, press the 'SEL' button
9
to toggle between AC and DC modes. The AC or DC icon on the
LCD indicates which mode has been selected. Note '
AC
' or '
DC
'
on the display.
2. Apply test leads to the circuit to be tested to measure the
voltage. The meter will auto-range to display the measurement
in the most appropriate range.
NOTE:
If '
–
' appears on the LCD, the test leads are being applied to
the circuit in reverse. Change the position of the leads to correct this.
NOTE:
When in a voltage setting and the test leads are open,
readings of the order mV may appear on the display. This is noise
and is normal. By touching the test leads together to close the
circuit, the meter will measure zero volts.
AC/DC LoZ VOLTAGE (LESS THAN 600 V)
1. Insert the RED test lead into the VΩ jack
5
and the BLACK
test lead into the COM jack
4
, and rotate the Function selector
switch
2
to the AC/DC LoZ voltage
setting. The meter
defaults to AC measurement. To measure DC, press the 'SEL'
button
9
to toggle between AC and DC modes. The AC or DC
icon on the LCD indicates which mode has been selected. Note
'
AC
' or '
DC
' on the display.
2. Apply test leads to the circuit to be tested to measure the
voltage. The meter will auto-range to display the measurement
in the most appropriate range.
Do not attempt to measure voltages greater than 600 V
in the LoZ setting.
Black lead Red lead
Black lead Red lead