Pag
e 8
Ther
e a
r
e t
w
o w
ay
s to c
arr
y o
u
t t
h
e c
onnectio
n to t
h
e m
ai
n g
a
s l
ine:
A. Th
e f
reestandin
g c
ooke
r c
a
n be c
onnecte
d w
it
h r
igi
d p
ip
e as s
pecifie
d in A
S/NZ
S 5
60
1 .
B. Th
e c
ooke
r c
a
n be c
onnecte
d w
it
h a F
lexibl
e H
ose
, w
hic
h c
omplie
s w
it
h A
S/NZ
S 1
869
(AG
A A
pproved)
, 1
0m
m I
D
, c
las
s B or D, n
o
t m
or
e t
ha
n 1
.2
m l
on
g a
n
d in a
ccordanc
e w
ith
AS/NZ
S 5
601
. E
nsur
e t
ha
t t
h
e h
os
e d
oe
s n
o
t c
ontac
t t
h
e h
o
t s
urface
s of t
h
e h
ob
, o
ven,
dishwashe
r or o
the
r a
ppliance
s t
ha
t m
a
y be i
nstalle
d u
nderneat
h or n
ex
t to t
h
e c
ooker.
WARNING:
Ensure that the hose assembly is not in contact with the flue or flue outlet of the oven.
The hose should not be subjected to abrasion, kinking or permanent deformation and should be
able to be inspected along its entire length. Unions compatible with the hose fittings must be used
and connections must be t
est
ed for gas leaks. The supply connection point shall be accessible af
t
er
the appliance is installed. The fixed consumer-piping outlet should be at appr
oximat
ely 150mm to
the side of the cook
er
. The hose should be clear of the floor when the cooker is installed.
CAUTION !!
Carry out the connection without applying any kind of stress to the appliance.
WARNING:
The restraint chain supplied should be anchored to the wall so that the chain prevents
strain on the hose connections when the cooker is pulled for
ward.
Af
ter gas connection, check for leaks using soapy solution, never a naked flame.
Setting of the gas pressure
Fit a manometer with a 6mm rubber hose to the test point on the NG regulator. Or fit the
manometer to LPG test point if ULPG connection is used.
Ignite the wok and auxiliary burner on and adjust test point pressure to 2.75kPa for ULPG and
1.00kPa for NG. Turn the two burners off and on again and recheck the pressure
to see
if it is the
same as previously set. Adjust again if required.
Test if the cooktop operates correctly
Af
ter installation and test point setting, each burner ignition and operation must be tested
individually and with all burners operating. This testing must be done by the installer before
leaving.
WARNING: THE BURNER FLAME MUST BE ADJUSTED BY THE INSTALLER. FAULTY
INSTALLATION IS NOT COVERED BY THE MANUFACTURER'S WARRANTY.
Supplied Gas Conversion
Contact the manufacturer or authorised dealer for conversion. For service, please refer to contact
details
on the back cover of this manual
.
Impor
tant:. Before carrying out the conversion, unplug the appliance from the gas and power
mains.
Replacing nozzles :
-
Unplug the appliance from the mains to avoid possible electrical shock
.
-
Remove the trivets from the
cooktop
-
Remove the burner caps
-
Use a 7mm tubular hex wrench to loosen the nozzles and replace them with suitable
nozzles as indicated in the diagram
on the following page
.
-
Remove or install regulator for NG or test point adaptor for ULPG.