Moving Unit to a New Location 

To prevent damage while moving the unit, the 
shipping materials MUST BE reinstalled.

Reinstallation of Shipping Materials

Disconnect washer from electrical supply.

Remove front access panel by removing two screws.

Place the shock sleeves on all four shock absorbers. 
Refer to 

Figure 14

.

Insert hooked end of shipping brace into the open slot 
of the motor mount. Attach with bolts and lockwashers. 
Refer to 

Figure 14

.

Reinstall front access panel.

Figure 14 

Refer to step 5 for proper procedures whenever the 
unit is moved.

Electrical Requirements

(240 Volt, 50 Hertz with 3-Prong Earthing Plug)

NOTE: The wiring diagram is located in the 
control hood.

Figure 15 

The washer is designed to be operated on a separate 
branch, polarized, three-wire, effectively earthed, 
240 Volt, 50 Hertz, AC (alternating current) circuit 
protected by a 

10 Ampere fuse

, equivalent fusetron or 

circuit breaker.

The three-prong earthing plug on the power cord 
should be plugged directly into a polarized three-slot 
effectively earthed receptacle rated 240 Volts AC 
(alternating current) 10 Amps. Refer to 

Figure 16

 to 

determine correct polarity of the wall receptacle.

H336I

1

Shock Sleeves

2

Motor Mount

3

Bolts and Lockwashers

4

Hooked End of Shipping Brace

2

1

4

3

D009I

To reduce the risk of fire, electric shock, 
serious injury or death, all wiring and 
earthing MUST abide with local electrical 
codes. It is the customer’s responsibility to 
have the wiring and fuses checked by a 
qualified electrician to make sure the 
laundry room has adequate electrical power 
to operate the washer.

W246

WARNING

DO NOT OVERLOAD 

CIRCUITS 

DO NOT USE AN 

ADAPTER

DO NOT USE AN 

EXTENSION CORD

Summary of Contents for LTK95A

Page 1: ...allation Frontload Washers Model LTK95A N3050 FLW1518C FLW1518C Part No 802116R1 May 2005 Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany mach...

Page 2: ......

Page 3: ...ctrical 6 Water 6 Accessories Bag 6 Installing the Washer 7 Step 1 Position Washer Near Installation Area 7 Step 2 Connect Fill Hoses 7 Step 3 Connect Drain Hose to Drain Receptacle 8 Step 4 Position...

Page 4: ...2 802116 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...

Page 5: ...3 802116 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Replacement Parts If replacement parts are required contact the source from which you purchased your washer...

Page 6: ...802116 4 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...

Page 7: ...ry Systems LLC DO NOT COPY or TRANSMIT Installation Dimensions and Specifications FLW2050N FLW2050N 71 1 cm 28 in 5 1 cm 2 in 47 5 cm 18 7 in 109 2 cm 43 in 36 3 cm 14 3 in 75 2 cm 29 6 in 79 cm 31 1...

Page 8: ...ressure between 138 and 827 kPa 20 to 120 pounds per square inch For more detailed information refer to section on Water Supply Requirements Accessories Bag An accessories bag has been shipped inside...

Page 9: ...ls that could clog the filter screens in the fill hoses or the screens in the water mixing valve NOTE When installing in newly constructed or renovated building it is very important to flush the lines...

Page 10: ...e sink wall or laundry tub Follow these instructions to properly install the drain hose IMPORTANT Drain receptacle must be capable of handling a minimum of 3 2 cm 1 1 4 inch outside diameter drain hos...

Page 11: ...during use Figure 6 Sink Installation For this type of installation use the beaded tie down strap supplied in accessories bag or use a large wire tie available from your local hardware store and secu...

Page 12: ...sories bag NOTE End of drain hose must not be below 61 cm 24 in Figure 8 Laundry Tub Installation For this type of installation the drain hose MUST be secured to the stationary tub to prevent hose fro...

Page 13: ...lide washer across floor if the leveling legs have been extended as legs and base could become damaged NOTE Use of the dispenser drawer or washer door as a handle in the transportation of the washer m...

Page 14: ...unit is moved IMPORTANT The shipping materials MUST be reinstalled whenever the unit is moved Refer to Moving Unit to a New Location section for proper instructions on reinstalling the shipping mater...

Page 15: ...her is designed to be operated on a separate branch polarized three wire effectively earthed 240 Volt 50 Hertz AC alternating current circuit protected by a 10 Ampere fuse equivalent fusetron or circu...

Page 16: ...aged it must be replaced by a special cord or assembly available from the manufacturer or its service agent Figure 16 DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT DO NOT OVERLOAD CIRCUITS Do no...

Page 17: ...gh for the installation Order hose as follows Part Number 1010102 2 5 m Fill Hose Figure 17 Water Pressure Pressure must be a minimum of 138 to a maximum of 827 kPa 20 to 120 pounds per square inch st...

Page 18: ...ers Risers or air cushions may have to be installed if the pipes knock or pound when flow of water stops The risers are more efficient when installed as close as possible to the water supply faucets r...

Page 19: ...y Reference Customer Care Centre and Information 1300 652 100 Date Purchased Model Number Serial Number Store Name Store Address Phone Number Service Agency Service Agency Address Phone Number NOTE Re...

Page 20: ...802116 18 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...

Page 21: ......

Page 22: ...ea CHECK 1 D772I D772I W520I Connect Fill Hoses CHECK 2 W520I FLW2010N Connect Drain Hose to Drain Receptacle CHECK 3 FLW2010N FLW2052N Position and Level the Washer CHECK 4 FLW2052N Remove the Shock...

Reviews: