E2 tree
Inspection
-
>
If the problem has not been solved through all the inspection mentioned
above, maybe the PCB has a malfunction. So, replace PCB and test again.
E2 code
Longer drain time
Some water
Check whether the Drain
Pump circuit is correct or
not. (mentioned in section
4)
solve the problem
Not
No water
Is there any
water in the Tub?
Reconnect the wire of
Drain Pump circuit and
check again
OK
Still wrong
Replace the Drain
pump to solve
problem
Make a check of Drain
Hose
solve the problem
Drain Hose is blocked
or kinked
OK
Failure
Failure
When there is no water in the
tub, check whether Pressure
Switch(83/63) circuit is open or
not, which control water inlet.
Reconnect the wire of
Pressure Switch circuit
and check again
OK
Still wrong
Replace the
Pressure Switch to
solve problem
Open
solve the problem
Note: This error 2 is only for models whose water filling be controlled by pressure switch(83/63).
-