After connecting the gas supply, check the piping and connections for leaks using a
soap and water solution. The presence of bubbles indicates a leak, tighten or
replace connections as appropriate.
>
Adjust the test point pressure or supply pressure to the value which is appropriate
for the gas type.
>
The operation of the appliance must be tested when installation is completed.
>
Turn on the appliance gas controls and light each burner individually and in
combination. Check for a well defined blue flame without any yellow tipping. If any
abnormality is evident then check that the burner cap is located properly and the
injector nipple is aligned correctly.
>
Check the minimum burner setting by quickly rotating the gas control knob from the
maximum to the minimum position, the flame must not go out. If adjustment is
required carry out the “minimum burner setting adjustment” procedure described.
>
If satisfactory performance cannot be obtained isolate the appliance and contact
the local gas authority for advice and assistance.
31
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use suitable seal)
Gas regulator
GAS CONNECTION FOR LPG-PROPANE
GAS CONNECTION FOR NATURAL GAS
Fig. 30a
Fig. 30b
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use suitable seal)
Test point adaptor