Instructions for use, installation and connection
7
Electronic timer
(FEC 500W
FEC 500X)
1
function button
2
minus (-) and plus (+) button
Manual
Timer
Period of operation
End
Current Time
Setting the current time
After connecting the appliance to the mains the
display indicates flashing 0 00 and the flashing
symbol S3. Turn button 1 to the position "current
time" or "manual", and by turning the button 2
towards "+" or "-" set the current time of day. The
clock starts running 7 seconds after the last touch of
any button. The symbol S1 is on, indicating that the
clock has been set to manual (conventional) mode.
Note: keeping button 2 turned towards the position
"+" or "-" speeds up the setting process on the
display.
Setting the conventional (manual)
operation
Turn the button 1 to the position "manual". All actual
running programs are hereby cancelled (the
symbol S3 is deleted if it was active). Symbol S1
becomes active (if it was not already on), which
means that the clock is set to the conventional
(manual) mode of operation.
Semi-automatic operation with the
defined period
Turn button 1 to the position "period of operation".
The display indicates 0 00 and the symbol S1 is
on. Set the desired period by turning button 2 to the
position "+" or "-". The symbol S3 appears. The
period of operation may be selected in steps of 1
minute. Maximum possible period to be set is 10
hours.
Once the desired period of operation is selected,
the time countdown starts after the 7 second lapse.
If button 1 remained in the position "manual" the
display indicates the countdown time.
The remaining time may be checked by turning
button 2, while button 1 must remain in the position
"period of operation".
The expiry of the set period is signaled by the
alarm, which is switched off automatically after 7
minutes, if it was not switched off before by turning
button 1 into any position other than the present
one. The symbol S1 is off and the symbol S3
flashes. In this moment the oven is switched off.
After turning the button 1 into the position
"manual" the symbol S3 turns off and the symbol
S1 reappears. The clock is set to conventional
(manual) mode.
If you wish to terminate roasting the oven
must be switched off!
Semi-automatic operation with the end
of operation
Turn button 1 to the position "end". The display
indicates the current time. Set the desired end of
operation time by turning button 2 towards the
position "+" or "-" (naturally, the end time must
be greater than the current time). The symbol S3
appears. The display returns to read current time
7 seconds after the setting process is completed.
Once the current time reaches the preset end of
operation time, this is signalled by the sound
alarm, which is switched off automatically after 7
minutes, if it was not switched off before by
turning button 1 to any direction. The symbol S1
is off and symbol S3 flashes. In this moment the
oven is switched off.
After turning button 1 into the position "manual"
the symbol S3 turns off and the symbol S1
reappears. The clock is set to conventional
(manual) mode.
If you wish to terminate roasting the oven
must be switched off!
Automatic operation with the preset
period and the end of operation
Turn button 1 to the position "period of operation"
and by turning button 2 towards "+" or "-" set the
period of cooking.
Then turn button 1 into the position "end" and the
display indicates the nearest possible end of
operation time. Set the desired end of operation
time by turning button 1 towards "+" or "-". The
symbol S1 is off if the end time is greater than the
current time + the preset period of operation.
The oven starts operating automatically according
to the preset times.
Example
Current time = 12:00, operation interval was set
at 1:30 and the end of operation at 14:00. This
means that the oven will start operating at 12:30.