5.   Remarks in respect of the determined use

 

 
Before starting the pressing process the charging levels of the 
battery cartridge (Pos.-#. 7) should be tested. A low charging level 
can for example be detected by a continued signal of the light 
diode display (Pos.-#. 6) for 20 sec. at the end of a test pressing 
cycle. (see chapter 4.3) 
 

5.1. Operation of the units

 

 
After having selected the right pressing dies (Pos.-No. 10) for the 
intended application the dies must be examined in terms of 
possible damage, dirt in the compression area and ware. When 
using competitor products the user has to make sure that the dies 
comply with this tool.  
 
After mounting the fitting on the tube the pressing jaws (Pos.-No. 
3) must be opened by pushing the rear end of the pressing jaw 
together while the jaw has to be positioned on the fitting. (Pls. see 
also picture 5 Pos. E) 
 
A pressing procedure will be initiated by actuating the trigger 
(Pos.-#. 1, Picture 2 Pos. B). The pressing process is defined by the 
closing motion of the pressing jaws. The drive rolls on top of the 
ram close the pressing jaws scissors like.  

 

Attention 
A necessary condition for a permanently leaking free 
connection is that the pressing cycle has to be completed 
which means that the pressing jaws completely closed at 
the tip as well as the T-link. 

 

Attention 
The assembly of gas pipes in gas distribution lines is 
prohibited unless the system provider gives an explicit 
permission to use this tool on special gas fittings. 

 

Attention 
The pressing procedure can be interrupted at any 
moment by releasing the trigger. 

 

Attention 
The user has to check by optical means whether the 
pressing jaws are completely closed.

 

 

Attention 
If a pressing cycle has been interrupted the fitting has to 
be either dismantled or pressed a second time.

 

 
The user needs to make sure that the pressing jaws are completely 
closed and that there are no foreign objects (e.g. plaster or stone 
fractions) between the pressing dies. 
 
In case of error or emergency push retract button (Pos. 2, Picture 2 
Pos. B) to return the drive rolls into starting position. 
 
The drive rolls retract automatically and return into the starting 
position after the maximum operating pressure has been reached 
enabling the user open the pressing jaw.  
 

Attention 
Before changing the pressing jaws remove 
battery to avoid unintentional operation.

 

 

 

5.2. Explanation of the application range

 

 
The UAP 32 is a hand guided pressing tool to mount fittings on multi 
Layer, copper and steel type plumbing tubes with 

 12 to 32 mm. The 

unit is not supposed to be restrained in a vise. It is not allowed to use the 
tool in a stationary application. Complying certain conditions the unit 
can be operated stationary with our presentation support EKST. The 
conditions can be taken from the instruction manual of the EKST. 
 
The tool is not designed for continued pressing operations. After a 
sequence of approximately 50 completed cycles you have to make a 
break of 15 minutes to give the unit time to cool down.  
 

Attention 
Too intensive use can cause heat damages for the tool 

 

Attention 
During the operation of electric motors sparks can occur 
which might ignite highly inflammable or explosive liquids 
and materials 

 

Attention 
Electric-hydraulic pressing tools must not be operated in 
pouring rain or under water. 

 

5.3. Mounting instructions

 

 
Please reference the assembly manual of the systems supplier before 
mounting the fittings on the tubes. In order to safeguard a proper 
pressing and to guaranty a safe and reliable handling the machine must 
only be operated with pressing dies recommended by the provider of the 
tube system and/or the tool manufacturer.  
 

Attention 
Do not press with bent or damaged pressing jaws. 

 

Remark 
As the tool manufacturer we offer perfectly designed pressing 
dies for all known systems and tube dimensions. Special 
designs and customer solutions upon request. 

 

5.4. Service and maintenance instruction 

 
The reliable performance of the tool is dependent on careful treatment 
and service. This represents an important condition to safeguard a lasting 
connection. To safeguard this the tool have to be maintained and 
serviced regularly (see chapter 4.3 for more information).  
We would like to draw your attention to the following points: 
1.  The electric-hydraulic pressing unit have to be cleaned and dried 

after each use before being put into the transportation case. 

2.  In order to guaranty a proper function of the machine the pressing 

tool should be returned to the manufacturer after the light diode 
display (Pos.-#. 6) indicates Service. 

3.  The battery as well as the charging unit must be protected against 

humidity and foreign objects. 

4.  The bolt joins, the drive rolls and their guides must be oiled 

regularly in small amounts. 

5.  Check through test crimps or have the tool manufacturer check the 

tool and pressing dies regularly for proper function. 

6.  Keep pressing dies clean. Remove dirt with a brush. 
In order to avoid possible malfunctions we offer you a manufacturer 
service consisting of disassembly, cleaning, exchange of possibly worn 
out parts assembly and final control. Only a clean and properly 
functioning press system can over the time safeguard a leaking free 
connection. 
 
Within the determined use of the tool only the pressing dies (Pos.-#. 10) 
are permitted to be changed by the customers. 
 

Attention 
Do not damage the seals of the tool. 
If the seals are damaged the warranty is invalidated. 

 

 

 

 

 

 

Summary of Contents for UAP 32

Page 1: ...n 14 Auf dem Knapp 46 Tel 49 0 2191 907 0 D 42855 Remscheid Fax 49 0 2191 907 141 __________________________________________________________________________________________________________________ Bed...

Page 2: ...32 Seite 2 ___________________________________________________________________________________________________________________ 4 10 3 5 6 1 2 9 11 7 Bild Picture 1 Bild Picture 3 Bild Picture 4 Bild P...

Page 3: ...Geh use Ergonomisch gestaltetes Kunst stoffgeh use mit Tankabdeckung 6 Leuchtdioden anzeige Kontrollinstrument zum Feststellen des Ladezustandes und weiterer Ger tefunktionen 7 Akku wiederaufladbarer...

Page 4: ...as Ger t darf nicht eingespannt werden Es ist nicht f r den station ren Einsatz ausgelegt UnterEinhaltung bestimmter Bedingungen kann das Ger t auch station r mit unserem Pr sentationsst nder EKST bet...

Page 5: ...en Akku nicht in Ihre Hosentasche oder in Ihre Werkzeugkiste wenn sich in ihnen leitf hige Teile befinden wie z B M nzen Schl ssel Werkzeuge oder andere metallische Teile Ziehen Sie den Stecker des La...

Page 6: ...5 Housing ergonomically formed plastic housing for perfect handling with a detachable lid 6 Light diode display indicator for tool functions and battery charge control 7 Battery cartridge rechargeable...

Page 7: ...posed to be restrained in a vise It is not allowed to use the tool in a stationary application Complying certain conditions the unit can be operated stationary with our presentation support EKST The c...

Page 8: ...e any conductive materials in it such as coins keys tools or other metallic parts The charging of the batteries must only be done with charging units supplied by the manufacturer Pull the plug of the...

Page 9: ...wnicze D wignia prasownicza do osadzania wk adek 4 G owica prasownicza Uchwyt szcz k prasowniczych poprzez kt ry szcz ki prasownicze po czone s obrotowo poprzez sworznie 5 Obudowa Ergonomiczna obudowa...

Page 10: ...eznaczone do u ytku stacjonarnego Narz dzie nie nadaje si do pracy ci g ej Po 50 kolejnych operacjach zaprasowywania nale y wprowadzi kr tk przerw co najmniej 15 min aby pozwoli na ostygni cie narz dz...

Page 11: ...nie wk ada do kieszeni spodni lub do skrzynki narz dziowej gdy znajduj si tam przewodz ce elektrycznie przedmioty np monety klucze narz dzia lub inne przedmioty metalowe Po adowaniu nale y wyj wtyczk...

Page 12: ...Galvani Electricidade Lda Mrs Anna Pereira Rua Serpa Pinto 15 A P 1200 Lisboa Portugal Tel 351 21 3223400 Fax 351 21 3223410 SLOWENIEN Isaria d o o Proizvdnja in trgovina Cece 2a 1420 Trovlje Slowenie...

Page 13: ...USSLAND Uni Mark Pro Mr Alexander Naichouller 119147 Moscow Aarksistskaya 4 Russland Tel 007 095 7480907 Fax 007 095 7480909 E Mail mark unit ru Geplante planned Service Center in 2003 LIBANON Georges...

Page 14: ...1 EN 28662 1 EN 50081 1 EN 50082 2 EN 60529 prEN 982 prEN 1037 de acuerdo con las regulaciones de las directivas 89 392 CEE 89 336 CEE P CE 99 Declara o de conformidade Declaramos sob nossa exclusiva...