17
EN
Problem
Possible Cause
Solution
No wind and no steam.
The sealing ring
on the air flue was
disassembled with
distortion.
Disassemble the air flue,
pour out the water and
clean the air flue. And
then assemble the valve
body and sealing ring to
the air flue without any
distortion.
The air flue was not
locked tight.
Other dirty on the air
flue and valve body.
Steam with peculiar
smell.
New device.
Open the top cover and
put the device in the
shady and cool place for
12 hours.
Dirty water or the water
in the tank for a long
time.
Clean the water tank and
replace the clean water.
Noise.
Less water in tank.
Add water.
Resonance with the table
surface.
Put the device on the
firm and flat place.
Steam out from outlet
surrounding.
Clearance between
steam outlet and water
tank.
Soak the nozzle into the
water and use it again.
There is water in the
tank, but the device
indicates waterless.
Something may stuck
the float and water can’t
flow out to the water
sink.
Take out the air flue
and clean it. And then
assemble it back to the
device.
Small mist output or
no mist output with
indicator on.
There are scales or some
dirty on the valve body.
The water can’t flow out
to the water sink.
Clean the air flue and
valve body and then try
again.