62
Step 6: connect wire of indoor unit
1. Make the power connection wire go through the
cable-cross hole of indoor unit and then pull it out.
2. Remove the wire clip; connect the power
connection wire to the wiring terminal according
to the color; tighten the screw and then fix the
power connection wire with wire clip.
3. Adjust the position of upper and lower adjusting
baffle; clamp the connection
4. Tighten the screws pipe and drain pipe as firm as
possible.
2. Bind the joint with tape.
drain hose
tape
outlet pipe
power connection wire
cable-cross hole
N(1)
2
blue black
yellow-
green
Outdoor unit connection
3
brown
Notes
All wires of indoor unit and outdoor unit should be connected by a professional.
• If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid
extending the wire by yourself.
• For the air conditioner with plug, the plug should be reachable after finishing installation.
• For the air conditioner without plug, an air switch must be installed in the line. The air switch should be all-
pole parting and the contact parting distance should be more than 3 mm.