AFL
ON
9
11
13
15
17
L
10
12
14
16
18
R
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ST
ST
talk
mic
level
MUTE
0
+10
headphone
solo add
mode
monitor
+6
0
The TALK XLR socket accepts
balanced 150 Ohm microphone
signals from - 50dBu to - 20dBu and
uses an auto ranging gain system to
bring the level to nominal 0dBu line
level.
The TALK control gives continuous
adjustment of the talk microphone
amplifier signal from + 6dB to off.
The TALK switch connects the talk
microphone input to the talk system
and at the same time dims the local
outputs by 20dB to prevent howl
round.
The HEADPHONE LEVEL control
gives continuous adjustment of the
headphone level from + 10dB to off.
The HEADPHONE MUTE switch
mutes the headphone outputs.
The SOLO ADD MODE switch
allows multiple channel access to
the solo busses. When the solo add
mode is off the action of pressing a
solo switch will cancel any
previously active solo. Multiple
solos such as stereo left and right
signals can be monitored in this
mode of operation as long as the
solo switches are pressed at
approximately the same time. When
the solo add mode is on the auto
cancelling is defeated which allows
multiple channel or output soloing.
In this mode input channel solos
have priority over the output solos,
i.e. any active input solo will
temporarily override all active
output solos; when the input solo is
cancelled the output solos will
return.
The MONITOR AFL switch sends
the stereo AFL solo bus signals to
the headphones and local outputs in
place of the mono PFL solo bus
signal.