5 DANTE 

• 

Audinate® Dante™ is a sophisticated audio network protocol for the professional transmission of audio with a multitude 

of channels, high sampling rates and it can also provide redundancy. 

!

  PLEASE NOTE:

 AVOID TRANSMITTING UNNECESSARY DATA

 ON THE DANTE NETWORK, E.G. SHARING BIG CHUNKS OF    

 

DATA BETWEEN COMPUTERS TO ENSURE HIGHEST STABILITY FOR THE AUDIO NETWORK.

DANTE VIRTUAL SOUNDCARD

• 

License available under: 

https://www.audinate.com/products/software/dante-virtual-soundcard

• 

In order to activate the virtual sound card, 

click on the power button

 on the left as shown in the following screenshot.  

  If it turns green, the sound card is active.

• 

Make sure the network connector is green and shows 

1G indicating a Gigabit

 connection. It does not work properly 

with 100 MBit/s. In case you have 100 Mbit, modify the network cable connection to connect your computer directly to 

KLANG:fabrik, e.g. to 

DANTE 1 port 

.

Summary of Contents for KLANG:fabrik

Page 1: ...USER MANUAL KLANG fabrik KLANG vier 1 KLANG technologies GmbH Aachen Germany 2014 All rights reserved V0 1 6 6 Oct 15 USER MANUAL ENGLISH...

Page 2: ...ILABLE KLANG fabrik or KLANG vier Mixing Desk Dante enabled or compatible with ADAT or Analog to Dante ADAT converters or Computer Windows or Mac OS X with a multi track playback software including Da...

Page 3: ...is commonly inserted into an existing setup between mixing desk and headpho ne amp or wireless in ear transmitters With Dante and optical audio compatible with ADAT most digital mixing desks can be co...

Page 4: ...vel monitoring outputs 16 balanced XLR NEUTRIK connectors analog line level outputs with flat frequency response starting from 5 Hz Upper roll off frequency depending on sampling rate 16Hz 20kHz 0 1 d...

Page 5: ...ontroller software 2 KLANG vier high class network interfaces with locking NEUTRIK EhterCon connectors 2 different configurations 2 equal network ports switch attached control separate control and Dan...

Page 6: ...rack bolts W H 46 5 7 5 cm ROUTING KLANG fabrik only Flexible audio routing of all available inputs and outputs sampling frequency must match Clock sync KLANG fabrik can act as an additional audio da...

Page 7: ...E 1 Internally the KLANG fabrik KLANG vier has a Gigabit network switch and all Ethernet Ports have the same functionality factory default Advanced port settings like redundant ports or separated cont...

Page 8: ...ATA BETWEEN COMPUTERS TO ENSURE HIGHEST STABILITY FOR THE AUDIO NETWORK DANTE VIRTUAL SOUNDCARD License available under https www audinate com products software dante virtual soundcard In order to act...

Page 9: ...ule starts with the same serial number KF K4 as KLANG fabrik KLANG vier PLEASE NOTE HIGHLIGHTED DEVICE NAMES IN RED INDICATE PROBLEMS WITH THE DANTE SETTINGS Please disable distracting multiple connec...

Page 10: ...to route the channels 1 8 of Dante to the channels 1 8 of the 3D in ear monitoring system we push the arrow to appear in the cell 9 from left to right and the cell 5 from top to bottom Dante channels...

Page 11: ...s signal with a different clock and green shows signals with the same clock Only inputs with a locked clock are unmuted Inputs with unlocked clock are muted to avoid loud artifacts CHANGE NUMBER OF US...

Page 12: ...E G DISABLE UMTS DATA TRANSMISSION ON A TABLET OR SMARTPHONE IF CONNECTION CANNOT BE ESTABLISHED CONFIG TWEAK CHANNEL SETTINGS Go to CONFIG and to the ROUTING tab and click press the first instrument...

Page 13: ...sables distracting features that are used to configure KLANG fabrik KLANG vier This mode mainly allows to mix and position the pre defined inputs for one chosen user of KLANG fabrik KLANG vier In musi...

Page 14: ...ss drum or bass a mono setting inside the head might be sufficient as the human ears have difficulties locating low frequency content SETTINGS FOR THE USER For musicians use the musician mode but log...

Page 15: ...KLANG fabrik has been tested and complies with EN55103 1 2009 EN 55103 2 2009 EN 55022 2006 CISPR 22 1997 CAN CSA CEI IEC CISPR 22 02 FCC 47 CFR Part 15 SAFETY UL 60065 7th Edition Rev 09 21 2012 CAN...

Page 16: ...USER MANUAL KLANG fabrik KLANG vier 16 KLANG technologies GmbH Aachen Germany 2014 All rights reserved V0 1 6 6 Oct 15...