9
above the kiln, which exceeds the outer dimensions of the
kiln 1 m in each direction. In order that the surrounding
materials do not ignite, suitable fire-proof materials of low
heat conductivity should be used. Calcium Silicate
insulation boards (15 mm) are particularly suitable and
available from builders & merchants.
3.3
Checking clamps
When putting toploader kilns in operation the lid clamps on the
kiln must be checked for strength and tightened if necessary
.
The test needs to be performed during first installation and
every 6 months in the first 2 years of operation (or after 30
firings, whatever occurs first).
After 2 years of operation this check must be carried out at
annual intervals.
3.4
Connection of exhaust pipe
Generally, all kilns are supplied with an exhaust pipe of
80mm which should be fixed with two threaded screws with
the sloped side in front of the side ventilation hole.
For a discharge to atmosphere a minimum 2 m
long (chimney effect) stovepipe (e. g. flexible
aluminium pipe
80 mm available from
KITTEC
®
) can be connected to the end of the
exhaust pipe (suitable size metal hose clamp)
and passed through a heat-resistant fairlead
(e.g. stone or concrete) to
the other side of the wall or ceiling to
open-air in an upward direction.
Precautions should be taken to prevent
rainwater entering the exhaust pipe and
to prevent the flue being influenced by
bad wind conditions.