Figure 3-6
Cable Support Assembly
3.5.8 Connection to Electrical Power Source - The red, blue and black wires of the Power Supply Cable
should be connected to an Electric Power Disconnect Switch or Circuit Breaker. This connection
should be made so that the hoist is phased properly. Refer to Section 3.6.10 for instructions on how to
check for correct power supply phase connection.
3.5.9 Fuse/Breaker Capacity -The hoist's power supply should be equipped with current overload protection
such as fuses, which should be selected for 110% to 120% of total listed full load amperage, and
should be dual element time-delay fuses. Refer to the motor nameplate for the full load amperage
draw.
3.5.10
Grounding - An improper or insufficient ground connection creates an electrical
shock hazard when touching any part of the hoist or trolley. In the Power Supply Cable the ground wire
will be either Green with Yellow stripe or solid Green. It should always be connected to a suitable
ground connection.
Standard Cable Exit
Cable Exit for Large Gauge Cable
(Greater than 0.55” Diameter)
Summary of Contents for TNER Series
Page 37: ...This Page Intentionally Left Blank 37...
Page 38: ...Figure 9 1 Housing and Motor Parts 38 9 1 Housing and Motor Parts...
Page 41: ...This Page Intentionally Left Blank 41...
Page 42: ...Figure 9 2 Gearing Parts 9 2 Gearing Parts 42...
Page 44: ...Figure 9 3 Hook Parts 9 3 Hook Parts 44...
Page 46: ...Figure 9 4 Chaining Parts 9 4 Chaining Parts 46...
Page 48: ...Figure 9 5 Electric Parts 9 5 Electric Parts 48...
Page 53: ...53 Appendix A Wiring Diagram...
Page 54: ...54...