8
Style 2: Direct wire strain relief
■
Use Phillips screwdriver to remove screws and slide
cord/conduit plate down and out.
■
Position cord/conduit plate as shown in the following
illustration.
■
Replace cord/conduit plate and insert screws.
■
Assemble a UL listed conduit connector in the opening.
■
Feed the flexible conduit through the strain relief, allowing
enough slack to easily attach wiring to the terminal block.
■
Tighten strain relief screw against the flexible conduit.
5.
Replace back panel and screws on rear of range.
6.
Complete installation following instructions for your type of
electrical connection:
4-wire
(recommended)
3-wire
(if 4-wire is not available)
Electrical Connection Options
A. Removable retaining nut
B. Strain relief
A
B
If your home has:
And you will be
connecting to:
Go to Section:
4-wire receptacle
(NEMA type 14-50R)
A UL listed,
250-volt
minimum,
40-amp, range
power supply
cord
4-wire connection:
Power supply cord
4-wire direct
A fused
disconnect or
circuit breaker
box
4-wire connection:
Direct wire
3-wire receptacle
(NEMA type 10-50R)
A UL listed,
250-volt
minimum,
40-amp, range
power supply
cord
3-wire connection:
Power supply cord
3-wire direct
A fused
disconnect or
circuit breaker
box
3-wire connection:
Direct wire
(12.7 cm)
5"
3"
(7.6 cm)
1"
(2.5 cm)