4-8
REMOVING THE HUMIDITY SENSOR &
CAVITY TEMPERATURE FUSE
1.
Unplug microwave oven or disconnect
power.
2.
Remove the cabinet from the microwave
oven (see page 4-2 for the procedure).
3.
Remove the screw from the left top brace
and remove the brace from the unit.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
4.
To remove the humidity sensor:
a) Remove the decorative panel and tilt it
forward (see page 4-3 for the proce-
dure).
c) Remove the two screws and the green
ground wire from the humidity sensor
and remove the sensor.
Left Brace
Screw
Cavity Temp Fuse Humidity Sensor
b) Disconnect the 3-wire sensor connec-
tor (red, black, & white wires) from the
control board at CN-F.
Electrical Shock Hazard
Connect green ground wire to ground
screw.
Failure to do so can result in death or
electrical shock.
Humidity Sensor Connector (CN-F)
Humidity Sensor
Ground Wire
Screw (1 of 2)