Mark Rear Wall

The microwave oven must be installed on a minimum of 1 wall 
stud, preferably 2, using a minimum of 1 lag screw, preferably 2.
1. Using measuring tape, find and clearly mark the vertical 

centerline of the opening.

A. Centerline

2. Align the centerline of the wall template with the centerline on 

the wall, making sure it is level, and that the top of the wall 
template abuts the bottom edge of the upper cabinet. Tape 
the wall template into place.

NOTES:

If the front edge of the upper cabinet is lower than the back 
edge, lower the wall template so that its top is level with the 
front edge of the cabinet.

If the wall template is damaged or unusable, measure and 
mark the wall with the dimensions described in Step 4.

3. Mark both end holes of the mounting plate through the wall 

template.

4. Remove the wall template and check the markings:

The bottom edge line must be 18

⁵⁄₁₆

" (46.5 cm) from the 

bottom of the upper cabinet, and must be level.

The end holes must be 15

¹⁄₂

" (39.4 cm) from the bottom 

edge of the upper cabinet, and must be on a level line with 
each other. They must each be 14

¹⁄₈

" (35.9 cm) from the 

centerline.

5. With the support tabs facing forward (see illustrations in 

“Locate Wall Stud(s)” section), align the mounting plate center 
markers to the centerline on the wall, making sure its bottom 
edge is aligned to the horizontal line drawn in Step 3, and that 
the end holes are properly marked. Make sure the mounting 
plate is level.

6. Holding the mounting plate in place, find the wall stud 

centerline(s) drawn in Step 2 of “Locate Wall Stud(s),” and 
mark at least 1, preferably 2 hole(s) through the mounting 
plate, closest to the wall stud centerline(s). See figures 1, 2 
and/or 3 in “Possible Wall Stud Configurations” in “Locate 
Wall Stud(s)” section. The blackened holes in the shaded 
areas are ideal hole locations.

7. Set the mounting plate aside.

Wall Venting Installation Only

8. Mark the centerline 3/8" (1 cm) down from the bottom edge of 

the upper cabinet.

9. Using measuring tape, measure out 6" (15.2 cm) on both sides 

of the centerline, and mark.

10. Measure down 4" (10.2 cm) from the mark made in Step 8, 

and mark.

11. Using a straightedge, draw the 2 horizontal, level lines through 

the marks made in steps 8 and 10.

12. Draw the 2 vertical, plumb lines down from the marks made in 

Step 9 to complete the 12" x 4" (30.5 x 10.2 cm) rectangle. 
This is the venting cutout area.

13. Cut a 3/4" (19 mm) hole in one corner of the cutout area.
14. Using a keyhole saw, cut out the venting cutout area.

Drill Holes in Rear Wall

In addition to being installed on at least 1 wall stud, the mounting 
plate must attach to the wall at both end holes. If the end holes 
are not over wall studs, use two 1/4-20 x 3" round-head bolts with 
toggle nuts; if 1 end hole is over a wall stud, use 1 lag screw and 
one 1/4-20 x 3" round-head bolt with toggle nut; or if both end 
holes are over wall studs, use 2 lag screws. Following are 
3 installation configurations.

Installation for No Wall Studs at End Holes 
(Figures 1 and 2)

1. Drill 3/4" (19 mm) holes through the wall at both end holes 

marked in Step 3 of “Mark Rear Wall.”

2. Drill 3/16" (5 mm) hole(s) into the wall stud(s) at the hole(s) 

marked in Step 6 of “Mark Rear Wall.” Refer to figures 1 and 2 
in “Possible Wall Stud Configurations” in “Locate Wall Stud(s)” 
section.

Installation for Wall Stud at One End Hole (Figure 3)

1. Drill a 3/16" (5 mm) hole into the wall stud at the end hole 

marked in Step 3 of “Mark Rear Wall.”

2. If installing on a second wall stud, drill a 3/16" (5 mm) hole into 

the wall stud at the other hole marked in Step 6 of “Mark Rear 
Wall.” Refer to Figure 3 in “Possible Wall Stud Configurations” 
in “Locate Wall Stud(s)” section.

3. Drill a 3/4" (19 mm) hole through the wall at the other end hole.

Installation for Wall Studs at Both End Holes (Figure 4)

1. Drill 3/16" (5 mm) holes into the studs at the end holes marked 

in Step 3 of “Mark Rear Wall.”

A. Rear wall
B. Wall template

C. Top of wall template must align with 

front edge of cabinet.

D. Front edge of upper cabinet

A

A

C

B

D

Upper cabinet bottom

Bottom of mounting plate

Mounting plate end hole

15

¹⁄₂

"

(39.4 cm)

18

⁵⁄₁₆

"

(46.5 cm)

14

¹⁄₈

"

(35.9 cm)

14

¹⁄₈

"

(35.9 cm)

Centerline

6" (15.2 cm)

6" (15.2 cm)

³⁄₈

" (1 cm)

Upper cabinet bottom

4" (10.2 cm)

Centerline

Summary of Contents for KHMC1857BSP

Page 1: ...ttach Mounting Plate to Wall 8 Prepare Upper Cabinet 8 Install the Microwave Oven 9 Install Filters 10 Complete Installation 10 VENTING DESIGN SPECIFICATIONS 11 ASSISTANCE 12 Replacement Parts 12 W10502372A You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell yo...

Page 2: ...g see Venting Design Specifications section Special Requirements For Wall Venting Installation Only Cutout must be free of any obstructions so that the vent fits properly and the damper blade opens freely and fully For Roof Venting Installation Only If you are using a rectangular to round transition piece 3 7 6 cm clearance needs to exist above the microwave oven so that the damper blade can open ...

Page 3: ... cm Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock WARNING GROUNDING INSTRUCTIONS SAVETHESE INSTRUCTIONS For all cord connected appliances The microwave oven must be grounded In the event of an electrical short circuit groundin...

Page 4: ...e Venting Design Specifications section NOTE Skip this section if you are using recirculation installation Keep the damper assembly in case the venting method is changed or the microwave oven is reinstalled in another location where wall or roof venting may be used To prepare the microwave oven for wall or roof venting the vent deflector L shaped metal bar must be installed and the appropriate dam...

Page 5: ...ing as shown Then secure with mounting screw Roof Venting Installation Only To Remove Roof Damper Vent Cover 1 Locate the roof damper vent cover on the top of the microwave oven 2 Using diagonal wire cutting pliers gently snip out the damper vent cover at the perforations 3 Save the cover for possible change of venting method in the future NOTE Do not install damper assembly at this time A Mountin...

Page 6: ...tions show examples of preferred installation configurations with the mounting plate No Wall Studs at End Holes Figure 1 No Wall Studs at End Holes Figure 2 NOTE If wall stud is within 6 15 2 cm of the vertical centerline see Mark Rear Wall section only recirculation or roof venting installation can be done Wall Stud at One End Hole Figure 3 Wall Studs at Both End Holes Figure 4 A End holes on mou...

Page 7: ...ure out 6 15 2 cm on both sides of the centerline and mark 10 Measure down 4 10 2 cm from the mark made in Step 8 and mark 11 Using a straightedge draw the 2 horizontal level lines through the marks made in steps 8 and 10 12 Draw the 2 vertical plumb lines down from the marks made in Step 9 to complete the 12 x 4 30 5 x 10 2 cm rectangle This is the venting cutout area 13 Cut a 3 4 19 mm hole in o...

Page 8: ...a lag screw into the other hole drilled in Step 2 of Installation for Wall Stud at One End Hole in the Drill Holes in Rear Wall section 7 Check alignment of mounting plate making sure it is level 8 Securely tighten the lag screw s and bolt Wall Studs at Both End Holes Figure 4 1 Position mounting plate on the wall 2 Insert lag screws into both end holes 3 Check alignment of mounting plate making s...

Page 9: ... in the wall cutout 6 Push microwave oven against mounting plate and hold in place NOTE If microwave oven does not need to be adjusted skip steps 7 9 7 If adjustment is required rotate microwave oven downward Using 2 or more people lift microwave oven off of mounting plate and set aside on a covered surface 8 Loosen mounting plate screws Adjust mounting plate and retighten screws 9 Repeat steps 3 ...

Page 10: ...peration of microwave oven by placing 1 cup 250 mL of water on the turntable and programming a cook time of 1 minute at 100 power Test vent fan and exhaust by operating the vent fan 4 If the microwave oven does not operate Check that a household fuse has not blown or that a circuit breaker has not tripped Replace the fuse or reset the circuit breaker If the problem continues call an electrician Ch...

Page 11: ... the damper to open fully If venting through the roof and rectangular to round transition is used be sure there is at least 3 7 6 cm of clearance between the top of the microwave oven and the transition piece See Rectangular to Round Transition illustration Rectangular to Round Transition NOTE The minimum 3 7 6 cm clearance must exist between the top of the microwave oven and the rectangular to ro...

Page 12: ...e oven model number and serial number Both numbers can be found on the model and serial number plate which is located behind the microwave oven door on the front frame of the microwave oven If you need additional assistance call us at our toll free number or visit our website listed in the User Instructions ReplacementParts If any of the installation hardware needs to be replaced call us at our to...

Reviews: