12
Connect the yellow/green earth wire to the terminal with the
symbol.
This wire must be longer than the other wires.
1.
Remove the terminal block cover (
A
) by undoing the screw and inserting the cover in the terminal
block hinge (
B
).
2.
Strip approx. 70 mm of sheathing from the power supply cable.
3.
Strip approx. 10 mm of sheathing from the wires. Insert the power supply cable into the cable clamp
and connect the wires to the terminal board as shown in the diagram next to the terminal board.
4.
Secure the power supply cable with the cable clamp.
5.
Close the cover (
C
) and screw it on the terminal block using the screw you removed before - point
(
1
).
Repeat the same procedure for the second terminal board.
Every time the hob is connected to the mains, it will carry out an automatic check which takes several
seconds.
Connect the appliance to the mains electricity supply using a multi-pole disconnector with a minimum
contact gap of 3 mm.
C
B
A
Electrical wiring
If the hob does not come with power supply cables, use two H05RR-F cables (connected to the two
terminal boards) for the electrical wiring as indicated in the table below.
Wires
Quantity x size
220-240 V ~ +
3 x 4 mm
2
220-240 V 3 ~ +
5 x 1.5 mm
2
380-415 V 3N ~ +
5 x 1.5 mm
2
380-415 ~ +
4 x 1.5 mm
2
380-415 V 3N ~
220-240 V ~
220-240 V ~ (AU and UK)
380-415 V 2N ~
220-240 V 3 ~
(Belgium only)
380-415 V 2N ~
(NL only)
23
0
V
23
0
V
23
0
V
23
0
V
23
0
V
23
0
V
23
0
V
23
0
V
23
0
V
23
0
V
23
0
V
Summary of Contents for KHIP5 90510