Page 1: ... these IMPORTANT Installer Leave installation Instructions with the homeowner Homeowner Keep Installation Instructions for future reference Save installation Instructions for local electrical inspector s use Write down the model and serial numbers before installing cooktop Both numbers are on the model serial rating plate located on the bottom of the cooktop Model Serial Part No 3192516 ...

Page 2: ...tact a qualified electrical installer to make sure that the electrical installation is correct and to make sure the electrical installation follows the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances WARNING To reduce the risk of fire electric shock or injury to perso...

Page 3: ...Note 24 61 era rainiraura when bottora of wood or rectal cabinet is protected by not less than 1 4 6 4 tara flarae retardant raiJiboard covered with not Jessthan No 28 MSG sheet steel 0 015 0 4 rare stainless stee_ 0 024 0 6 rata aJurainura or 020 0 5 rata copper 30 76 2 cra rainiraura clearance between the top of the cooking p_atforra and bottom of unprotected wood or sheet metal coaetertop insta...

Page 4: ...e metal vent For attitudes above 4 800 ft 1372 m reduce recommended vent run by 20 For the most efficient and quietest operation Use 26 gauge minimum galvanized or 25 gauge minimum aluminum metal vent Poor quality pipe fittings can reduce air flow Note Local codes may require a heavier gauge material Flexible metal vent is Not recommended Do Not exhaust more than one downdraft cooktop into a singl...

Page 5: ... equivalent length of vent Maximum equivalent length of vent is 60 ft 18 3 m List the number of each piece and length of straight vent you will use Multiply the equivalent length by the number of pieces Add the totals to get the total equivalent length of your system Vent Piece straight vent per lineal foot 3 I 4 x 10 8 3 x 254 cm 6 152 cm round 1 ft 30 5cm 1ft 30 5cm 6 152 cm flexible 2 ft elbow ...

Page 6: ... the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and 22 2 No 0 M91 latest edition and all local codes and ordinances Wire sizes and connections must conform with the rating of the cooktop Copies of the standard listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusett...

Page 7: ... white greenor bare ground wire greenground ap pliance cable wire Figure 1 black wires conduit connector powersupply cablefromcooktop If local codes DO NOT PERMIT connecting cooktop ground conductor to neutral white wire in junction box four wire system 7 Connect the green ground power supply cable wire to the ground wire in junction box or other ground connector with twist on connector See Figure...

Page 8: ... call is free within the continental United States In Canada call 1 800 461 5681 for English and 1 800 461 5703 for French Or visit our web site at www kitchenaid com When you call you will need the cooktop model number and serial number Both numbers can be found on the model serial rating plate located on the bottom of the cooktop If you need service Consult your Use Care Guide In the event that ...