5-2
CONVECTION BAKE ELEMENT
Refer to page 4-18 for the procedure for ser-
vicing the convection bake element.
1.
Turn off gas supply and disconnect power
to the range.
2.
Disconnect the wires from the convection
bake element terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
convection bake element terminals. The
meter should indicate 33 to 37
Ω
.
BLOWER MOTOR
Refer to page 4-20 for the procedure for ser-
vicing the blower motor.
1.
Turn off gas supply and disconnect power
to the range.
2.
Disconnect the wires from the blower
motor’s terminals.
3.
Set the ohmmeter to the R X 1 scale.
4.
Touch the ohmmeter test leads to the
motor terminals. The meter should indi-
cate 14 to 18
Ω
.
Motor
Terminals
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.