18
PERFORMANCE DATA SHEETS
Base Grille Water Filtration System
Model T2WG2L/T2RFWG2 Capacity 200 Gallons (757 Liters)
Model T2WG2/T2RFWG2 Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Use replacement filter T2RFWG2, part #4396841.
Model T2WG2L: Style 1 –
When the filter indicator reads 10%,
order a new filter. When the indicator reads 0%, it is
recommended that you replace the filter.
Style 2 –
When the filter indicator changes from green to yellow,
order a new filter. When the indicator changes from yellow to red,
it is recommended that you replace the filter.
Style 3 –
When the water filter status display changes from
“GOOD” to “ORDER,” order a new filter. When the filter indicator
reads “REPLACE,” it is recommended that you replace the filter.
Style 4 –
Press FILTER to check the status of your water filter. If
the filter indicator light is yellow, order a new filter. If the filter
indicator light is red, it is recommended that you replace the filter.
Model T2WG2:
Change the water filter cartridge every 6 months.
If the water flow to the water dispenser or ice maker decreases
noticeably before 6 months have passed, replace the water filter
cartridge more often.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
Refer to the “Warranty” section for the Manufacturer’s name,
address and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class II*; and against NSF/ANSI Standard 53 for the reduction of Mercury,
Benzene, Toxaphene, O-dichlorobenzene, and Carbofuran.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor
Particulate Class II
*
50% reduction
85% reduction
2.0182 mg/L
1333333 #/mL
2.0 mg/L ± 10%
At least 10,000 particles/mL
0.06 mg/L
6600 #/mL
**
0.0536 mg/L
2325 #/mL
97.03
99.51
97.34
99.83
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Lead: @ pH 6.5***
Lead: @ pH 8.5***
0.010 mg/L
0.010 mg/L
0.1533 mg/L
0.1400 mg/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.0005 mg/L
0.0007 mg/L
0.0005 mg/L
0.0006 mg/L
99.67
99.50
99.67
99.57
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.0058 mg/L
0.0059 mg/L
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.0002 mg/L
0.0005 mg/L
0.0002 mg/L
0.0003 mg/L
96.54
91.57
96.54
94.92
Benzene
0.005 mg/L
0.0154 mg/L
0.015 mg/L ± 10%
0.0012 mg/L
0.0006 mg/L 92.22
96.34
O-Dichlorobenzene
0.6 mg/L
1.7571 mg/L
1.8 mg/L ± 10%
0.0250 mg/L
0.0066 mg/L 98.58
99.63
Toxaphene
0.003 mg/L
0.015 mg/L
0.015 mg/L ± 10%
0.001 mg/L
0.001 mg/L
93.33
93.33
Carbofuran
0.04 mg/L
0.0819 mg/L
0.08 mg/L ± 10%
0.0400 mg/L
0.0213 mg/L 51.13
74.00
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.85 gpm (3.2 Lpm) @ 60 psi
*
**
***
Class II particle size: 1 um to <5 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc.
® NSF is a registered trademark of NSF International.
Summary of Contents for KBSD602ESS-SS
Page 20: ...20 NOTES ...