Venting system must terminate to the
outside.

Do Not terminate the vent system in an
attic or other enclosed space.

Do Not use 4-inch (10 cm) laundry-type
wall caps.

Use metal vent only. Exception: See
"optional venting under a concrete
slab", in "Venting methods" below.
Rigid metal vent is recommended. Do
not use plastic or metal foil vent.

To reduce risk of fire and to properly
exhaust air, be sure to vent air outside.

Do Not vent exhaust air into spaces
within walls or ceilings or into attics,
crawl spaces or garages.

Before making cutouts, make sure there
is proper clearance within the wall or
floor for the exhaust vent.

Do Not cut a joist or stud unless
absolutely necessary. If a joist or stud
must be cut, then a supporting frame
must be constructed.

Vent materials needed for installation
are not supplied.

Determine which venting method to use.
See  “Venting methods,” below.
Next, determine the equivalent vent length
using chart on Page 5. The maximum
equivalent vent length is 60 feet (18.3 m).

For the most efficient and
quietest operation:

Use 26-gauge minimum galvanized or
25-gauge minimum aluminum metal
vent. Poor-quality pipe fittings can
reduce air flow. (Note: Local codes may
require a heavier-gauge material.)
Flexible metal vent is Not
recommended.

Venting system requirements

The cooktop may be vented through the wall or floor. Common venting methods and the
types of materials needed are shown.

Make sure there is proper clearance within the wall or floor for exhaust vent before
making cutouts.

17"

(43.2 cm)

9-5/8" (24.4 cm) - 30" (76.2 cm) cooktop

13-5/16" (33.8 cm) - 36" (91.4 cm) cooktop

9-3/4" (24.8 cm) 

hole in rear or 

side of cabinet

Venting methods

inside wall

cabinet

3-1/4" x 10"

(8.3 x 25.4 cm)

transition

elbow

3-1/4" x 10"

(8.3 x 25.4 cm)

transition

elbow

inside wall to roof 

or overhang

outside wall 

cabinet

directly
outside

peninsula

or island

peninsula

between 

floor joists

cabinet toe space 

to outside

The blower housing is set to vent
straight out the back from the cooktop. To
vent down, left or right, see “Installation,”
Step 2, Page 6.

This downdraft cooktop is rated at 
60 feet (18.3 m) of straight vent or the
equivalent.

•  If vent length is 10 feet (3 m) or less,

6" (15.2 cm) diameter round vent may 
be used.

•  If vent length is more than 10 feet 

(3 m), use 6" (15.2 cm) diameter round 
or 3-1/4" x 10" (8.3 x 25.4 cm) 
rectangular vent.

Thermal breaks: In areas of extreme
cold weather, it may be necessary to
provide a short length of nonmetallic duct
as close to the wall as possible to prevent
thermal conduction along the metal vent.

For altitudes above 4,500 ft (1372 m),
reduce recommended vent run by 20%.

Do Not exhaust more than one
downdraft cooktop into a single vent
system.

The length of vent and number of
elbows should be kept to a minimum to
provide efficient performance.

The size of the vent should be uniform.

Use the fewest number of 90° elbows.

Do Not install two elbows together.

Make sure there is a minimum of 18"
(45.7 cm) of straight vent between the
elbows if more than one elbow is used.
(Elbows too close together cause
excess turbulence that reduces airflow.)

Do Not use a 5" (12.7 cm) elbow in a 

6" (15.2 cm) or 3-1/4" x 10" 
(8.3 x 25.4 cm) system.

Do Not reduce back to 5" (12.7 cm)

system after using 6" (15.2 cm) or 
3-1/4" x 10" (8.3 x 25.4 cm) fittings.

Avoid forming handmade crimps.

Handmade crimps may restrict airflow.

Use the recommended vent caps for
proper performance. If an alternate wall
or roof cap is used, be certain cap size
is not reduced and that it has a
backdraft damper.

Use duct tape to seal all joints in the
vent system.

Use caulking to seal exterior wall or roof
opening around the cap.

Summary of Contents for 8285364

Page 1: ...nd serial numbers before installing cooktop Both numbers are on the model serial rating plate located on the bottom of the cooktop Model ___________________________ Serial ___________________________ Questions regarding features operation performance parts or service Call 1 800 422 1230 or visit our web site at www kitchenaid com IMPORTANT Read and save these instructions 30 76 2 cm and 36 91 4 cm...

Page 2: ...ion is correct and to make sure the electrical installation follows the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances tape measure hand or electric drill metal snips duct tape pliers gloves safety glasses caulking gun with weatherproof caulking Phillips screwdriver ...

Page 3: ...ration Decorative laminate Chamfer all exposed edges to prevent chipping laminate Cut radius corners and file to smooth edges and to prevent cracking 2 5 1 cm minimum space to front edge of countertop Install rear wall junction box in shaded area Darker shaded area is preferred Select required duct cutout see Page 4 for exhaust duct cutout location Countertop must be supported within 3 7 6 cm of c...

Page 4: ...ransition elbow 3 1 4 x 10 8 3 x 25 4 cm transition elbow inside wall to roof or overhang outside wall cabinet directly outside peninsula or island peninsula between floor joists cabinet toe space to outside The blower housing is set to vent straight out the back from the cooktop To vent down left or right see Installation Step 2 Page 6 This downdraft cooktop is rated at 60 feet 18 3 m of straight...

Page 5: ... 5 ft 90 elbow 1 5 m transition to round 3 1 4 x 10 8 3 x 25 4 cm to 9 ft 6 15 2 cm 90 elbow 2 7 m 3 1 4 x 10 8 3 x 25 4 cm to 4 5 ft 6 15 2 cm 1 4 m transition to flat 6 15 2 cm to 3 1 4 x 10 5 ft 8 3 x 25 4 cm 90 elbow 1 5 m 6 15 2 cm to 1 ft 3 1 4 x 10 8 3 x 25 4 cm 30 5 cm wall cap 3 1 4 x 10 8 3 x 25 4 cm 0 ft 0 cm 6 15 2 cm round 0 ft 0 cm roof cap 10 x 10 25 4 X 25 4 cm 0 ft 0 cm thermal br...

Page 6: ...and all local codes and ordinances Wire sizes and connections must conform with the rating of the cooktop Copies of the standard listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Canadian Standard Association 178 Rexdale Boulevard Etobicoke Ontario M9W 1R3 The wiring diagram is located on the bottom of the cooktop Twist on connectors and ...

Page 7: ...ire system If local codes PERMIT connecting cooktop ground conductor to neutral junction box wire three wire system Figure 1 power supply cable from cooktop junction box U L listed conduit connector red wires white wire black wires green ground appliance cable wire green or bare ground wire Figure 2 junction box red wires white wire cable from fused disconnect or circuit breaker box black wires po...

Page 8: ...at wire connections are intact See Use and Care Guide for troubleshooting list If you need assistance The KitchenAid Consumer Assistance Center is open 24 hours a day 7 days a week Call 1 800 422 1230 The call is free within the continental United States In Canada call 1 800 461 5681 for English and 1 800 461 5703 for French Or visit our web site at www kitchenaid com When you call you will need t...

Page 9: ...uméros de modèle et de série avant d installer la table de cuisson On trouve ces deux numéros sur la plaque signalétique située sur le fond de la caisse de la table de cuisson N de modèle N de série Pour des questions concernant les caractéristiques le fonctionnement la performance les pièces accessoires ou le service composer le 1 800 422 1230 ou consulter www kitchenaid com IMPORTANT Lire et con...

Page 10: ...alisations qui peuvent s y trouver Le conduit d évacuation associé à un ventilateur doit toujours décharger l air à l extérieur AVERTISSEMENT Pour réduire le risque d incendie utiliser uniquement des conduits métalliques La table de cuisson à aspiration vers le bas n est pas approuvée pour utilisation dans les habitations mobiles Des exemplaires des normes indiquées peuvent être obtenus aux adress...

Page 11: ...lacard inférieur de 76 2 cm 30 po profondeur de placard inférieur de 61 cm 24 po profondeur de dessus de comptoir de 63 5 cm 25 po Les dimensions de l ouverture dans le comptoir indiquées doivent être utilisées Les dimensions données sont les dégagements minimums et fournissent le dégagement requis de 0 cm 0 po Nouvelles installations Suivre les dimensions minimales données 12 7 cm 5 po 43 2 cm 17...

Page 12: ...4 4 cm 9 5 8 po table de cuission 76 2 cm 30 po 33 8 cm 13 5 16 po table de cuission 91 4 cm 36 po trou de 24 8 cm 9 3 4 po à l arrière ou sur le côté du placard Méthodes d évacuation placard de mur intérieur 8 3 x 25 4 cm 3 1 4 x 10 po coude de transition 8 3 x 25 4 cm 3 1 4 x 10 po coude de transition à l intérieur du mur jusqu au toit ou surplomb placard de mur extérieur directement vers l exté...

Page 13: ...le calcul de la longueur maximale du système d évacuation Il faut utiliser une bouche de décharge à travers le mur ou le toit convenable option circuit d évacuation installé sous une dalle de béton dans une fosse de fenêtre coude de 90 15 2 cm 6 po coude de 90 15 2 cm 6 po bouche de décharge murale 15 2 cm 6 po 61 cm 2 pi 1 2 m 4 pi Remarque On déconseille l emploi d un conduit d évacuation flexib...

Page 14: ...t obtenir des exemplaires des normes mentionnées auprès de National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Association canadienne de normalisation CSA 178 Rexdale Boulevard Etobicoke Ontario M9W 1R3 Le schéma de câblage se trouve à la base de la table de cuisson Les connecteurs vissables et les connecteurs de conduit 12 7 mm 1 2 po homologation UL ne sont pas four...

Page 15: ...terre de la table de cuisson au fil neutre blanc de la boîte de connexion système à trois fils Figure 1 boîte de connexion connecteur de conduit homologué U L fils rouge fil blanc fils noirs fil de liaison à la terre du câble d alimentation de l appareil fil de liaison à la terre nu ou vert Figure 2 boîte de connexion fils rouge fil blanc câble du sélectionneur à fusible ou du boîtier des disjonct...

Page 16: ...lisation et d entretien pour la liste de dépannage Si vous avez besoin d assistance Le Centre d assistance à la clientèle KitchenAid est accessible 24 heures par jour 7 jours par semaine Téléphoner au 1 800 422 1230 La communication est gratuite dans les limites du territoire continental des États Unis Au Canada composer pour l anglais 1 800 461 5681 ou pour le francais 1 800 461 5703 Ou visitez n...

Reviews: