background image

Before you start...

Tools and materials needed for installation:

This is the safety alert

symbol.This symbol alerts
you to hazards that can kill

or hurt you and others. All safety
messages will be preceded by the
safety alert symbol and the word
“DANGER” or “WARNING”. These
words mean:

You can be killed or seriously
injured if you don’t follow
instructions.

DANGER

Your safety and the safety of
others is very important.

We have provided many important
safety messages in this manual and
on your appliance. Always read and
obey all safety messages.

All safety messages will identify the
hazard, tell you how to reduce the
chance of injury, and tell you what
can happen if the instructions are
not followed.

You will be killed or seriously
injured if you don’t follow
instructions.

Parts supplied:

WARNING

2

cabinet storage is to be provided, the
risk can be reduced by installing a
range hood that projects horizontally a
minimum of 5 inches (12.7 cm) beyond
the bottom of the cabinets.

Proper installation is your responsibility.

• Make sure you have everything 

necessary for correct installation.

• Have a qualified technician install 

this cooktop.

• Comply with the electrical specifications 

on the model/serial rating plate.
Model/serial rating plate is located on 
the bottom of the cooktop. Write both 
numbers down on the front cover now 
before installing cooktop.

Downdraft cooktop location should be
away from strong draft areas, such as
windows, doors and strong heating vents
or fans. Locate cooktop for convenient
use in kitchen.

Grounded electrical system is required.
See “Electrical requirements,” Page 6.

Venting system must terminate
outdoors.

All openings in the wall or floor where
cooktop is to be installed must be
sealed.

It is the customer’s responsibility to
contact a qualified electrical installer,
to make sure that the electrical
installation is correct, and to make
sure the electrical installation follows
the National Electrical Code,
ANSI/NFPA 70 — latest edition*, or
CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No.
0-M91 - latest edition**, and all local
codes and ordinances.

tape measure

hand or

electric drill

metal 
snips

duct tape

pliers

gloves

safety
glasses

caulking gun with
weatherproof caulking

Phillips

screwdriver

Not shown:
• wall or roof cap (not supplied)
• metal vent
• twist-on connectors and 1/2" UL-listed conduit

connector. Number and size will depend on your
installation. See “Electrical connection,” Page 7.

• literature pack
• vent cover
• glass cleaner

WARNING: To reduce the risk of fire,
electric shock, or injury to persons,
observe the following:

Installation work and electrical wiring
must be done by qualified person(s) in
accordance with all applicable codes
and standards, including fire-rated
construction.

Sufficient air is needed for proper
combustion and exhausting of gases
through the flue (chimney) of fuel
burning equipment to prevent back
drafting. Follow the heating equipment
manufacturer’s guideline and safety
standards such as those published by
the American Society for Heating,
Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local
code authorities.

When cutting or drilling into wall or
ceiling, do not damage electrical wiring
and other hidden utilities.

Ducted fans must always be vented to
the outdoors.

WARNING: To reduce the risk of fire,
use only metal ductwork.

This downdraft cooktop is Not approved
for use in mobile homes.

Copies of the standards listed may be 
obtained from:

*

National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269

** Canadian Standard Association

178 Rexdale Boulevard
Etobicoke, (Toronto), Ontario M9W 1R3

Important: Observe all governing
codes and ordinances. Failure to meet
codes and ordinances could lead to
fire or electrical shock.

To eliminate the risk of burns by
reaching over heated surface units,
cabinet storage space located above
the surface units should be avoided. If

Summary of Contents for 8285364

Page 1: ...nd serial numbers before installing cooktop Both numbers are on the model serial rating plate located on the bottom of the cooktop Model ___________________________ Serial ___________________________ Questions regarding features operation performance parts or service Call 1 800 422 1230 or visit our web site at www kitchenaid com IMPORTANT Read and save these instructions 30 76 2 cm and 36 91 4 cm...

Page 2: ...ion is correct and to make sure the electrical installation follows the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances tape measure hand or electric drill metal snips duct tape pliers gloves safety glasses caulking gun with weatherproof caulking Phillips screwdriver ...

Page 3: ...ration Decorative laminate Chamfer all exposed edges to prevent chipping laminate Cut radius corners and file to smooth edges and to prevent cracking 2 5 1 cm minimum space to front edge of countertop Install rear wall junction box in shaded area Darker shaded area is preferred Select required duct cutout see Page 4 for exhaust duct cutout location Countertop must be supported within 3 7 6 cm of c...

Page 4: ...ransition elbow 3 1 4 x 10 8 3 x 25 4 cm transition elbow inside wall to roof or overhang outside wall cabinet directly outside peninsula or island peninsula between floor joists cabinet toe space to outside The blower housing is set to vent straight out the back from the cooktop To vent down left or right see Installation Step 2 Page 6 This downdraft cooktop is rated at 60 feet 18 3 m of straight...

Page 5: ... 5 ft 90 elbow 1 5 m transition to round 3 1 4 x 10 8 3 x 25 4 cm to 9 ft 6 15 2 cm 90 elbow 2 7 m 3 1 4 x 10 8 3 x 25 4 cm to 4 5 ft 6 15 2 cm 1 4 m transition to flat 6 15 2 cm to 3 1 4 x 10 5 ft 8 3 x 25 4 cm 90 elbow 1 5 m 6 15 2 cm to 1 ft 3 1 4 x 10 8 3 x 25 4 cm 30 5 cm wall cap 3 1 4 x 10 8 3 x 25 4 cm 0 ft 0 cm 6 15 2 cm round 0 ft 0 cm roof cap 10 x 10 25 4 X 25 4 cm 0 ft 0 cm thermal br...

Page 6: ...and all local codes and ordinances Wire sizes and connections must conform with the rating of the cooktop Copies of the standard listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Canadian Standard Association 178 Rexdale Boulevard Etobicoke Ontario M9W 1R3 The wiring diagram is located on the bottom of the cooktop Twist on connectors and ...

Page 7: ...ire system If local codes PERMIT connecting cooktop ground conductor to neutral junction box wire three wire system Figure 1 power supply cable from cooktop junction box U L listed conduit connector red wires white wire black wires green ground appliance cable wire green or bare ground wire Figure 2 junction box red wires white wire cable from fused disconnect or circuit breaker box black wires po...

Page 8: ...at wire connections are intact See Use and Care Guide for troubleshooting list If you need assistance The KitchenAid Consumer Assistance Center is open 24 hours a day 7 days a week Call 1 800 422 1230 The call is free within the continental United States In Canada call 1 800 461 5681 for English and 1 800 461 5703 for French Or visit our web site at www kitchenaid com When you call you will need t...

Page 9: ...uméros de modèle et de série avant d installer la table de cuisson On trouve ces deux numéros sur la plaque signalétique située sur le fond de la caisse de la table de cuisson N de modèle N de série Pour des questions concernant les caractéristiques le fonctionnement la performance les pièces accessoires ou le service composer le 1 800 422 1230 ou consulter www kitchenaid com IMPORTANT Lire et con...

Page 10: ...alisations qui peuvent s y trouver Le conduit d évacuation associé à un ventilateur doit toujours décharger l air à l extérieur AVERTISSEMENT Pour réduire le risque d incendie utiliser uniquement des conduits métalliques La table de cuisson à aspiration vers le bas n est pas approuvée pour utilisation dans les habitations mobiles Des exemplaires des normes indiquées peuvent être obtenus aux adress...

Page 11: ...lacard inférieur de 76 2 cm 30 po profondeur de placard inférieur de 61 cm 24 po profondeur de dessus de comptoir de 63 5 cm 25 po Les dimensions de l ouverture dans le comptoir indiquées doivent être utilisées Les dimensions données sont les dégagements minimums et fournissent le dégagement requis de 0 cm 0 po Nouvelles installations Suivre les dimensions minimales données 12 7 cm 5 po 43 2 cm 17...

Page 12: ...4 4 cm 9 5 8 po table de cuission 76 2 cm 30 po 33 8 cm 13 5 16 po table de cuission 91 4 cm 36 po trou de 24 8 cm 9 3 4 po à l arrière ou sur le côté du placard Méthodes d évacuation placard de mur intérieur 8 3 x 25 4 cm 3 1 4 x 10 po coude de transition 8 3 x 25 4 cm 3 1 4 x 10 po coude de transition à l intérieur du mur jusqu au toit ou surplomb placard de mur extérieur directement vers l exté...

Page 13: ...le calcul de la longueur maximale du système d évacuation Il faut utiliser une bouche de décharge à travers le mur ou le toit convenable option circuit d évacuation installé sous une dalle de béton dans une fosse de fenêtre coude de 90 15 2 cm 6 po coude de 90 15 2 cm 6 po bouche de décharge murale 15 2 cm 6 po 61 cm 2 pi 1 2 m 4 pi Remarque On déconseille l emploi d un conduit d évacuation flexib...

Page 14: ...t obtenir des exemplaires des normes mentionnées auprès de National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Association canadienne de normalisation CSA 178 Rexdale Boulevard Etobicoke Ontario M9W 1R3 Le schéma de câblage se trouve à la base de la table de cuisson Les connecteurs vissables et les connecteurs de conduit 12 7 mm 1 2 po homologation UL ne sont pas four...

Page 15: ...terre de la table de cuisson au fil neutre blanc de la boîte de connexion système à trois fils Figure 1 boîte de connexion connecteur de conduit homologué U L fils rouge fil blanc fils noirs fil de liaison à la terre du câble d alimentation de l appareil fil de liaison à la terre nu ou vert Figure 2 boîte de connexion fils rouge fil blanc câble du sélectionneur à fusible ou du boîtier des disjonct...

Page 16: ...lisation et d entretien pour la liste de dépannage Si vous avez besoin d assistance Le Centre d assistance à la clientèle KitchenAid est accessible 24 heures par jour 7 jours par semaine Téléphoner au 1 800 422 1230 La communication est gratuite dans les limites du territoire continental des États Unis Au Canada composer pour l anglais 1 800 461 5681 ou pour le francais 1 800 461 5703 Ou visitez n...

Reviews: