![Kitagawa MR250RAE13 Instruction Manual Download Page 24](http://html1.mh-extra.com/html/kitagawa/mr250rae13/mr250rae13_instruction-manual_1972455024.webp)
18
7-5. Solenoid Valve for Clamp and Unclamp
For Pneumatic Clamping, a solenoid valve is equipped inside.
Please refer to the specification drawn in outside view and wiring diagram.
【
Excitation Unclamp Spec.
】
Solenoid: ON
・・・
Unclamp
Solenoid: OFF
・・・
Clamp
【
Excitation Clamp Spec.
】
Solenoid: ON
・・・
Clamp
Solenoid: OFF
・・・
Unclamp
Since there is polarity in the pressure switch by SMC
CORP., a proximity switch
、
and a solenoid valve, please
refer to the wiring diagram.
8. Mounting the Workpiece
Securely mount the workpiece to the unit. If this is not done
properly, it may cause severe injury and/or accident as well
as poor indexing accuracy.
Avoid mounting a workpiece which has poor flatness or
perpendicularity directly to a table face. This may strain the
table and prevent smooth rotation, which may result in very
poor indexing accuracy. Shimming may be required to
prevent this problem.
Clamp the work in equipartition on the rotary table as much
as possible.
CAUTION
WARNING
CAUTION
CAUTION