Kisae 3000W - 120V Owner'S Manual Download Page 9

 

 

 

 

Page 

 

E06 

AC output load connected is close 
to overload limit 

Reduce load 

E07 

Internal temperature is high and is 
close to shutdown limit 

Reduce load and check if any ventilation 
of the unit is blocked 

 
AC Load on Inverter 
Although the Power Inverter can provide high surge power up to two times the rated output power, 
some high surge loads like sump-pumps, heavy duty motors etc. may still trigger the inverter 
protection system even though the load falls within the power rating of the inverter. A higher power 
Inverter is required for these appliances. 
Important: Each 3-pin AC socket provided can only handle 20A AC current. For appliances that 
require more than 2400W (20A) AC Power, hardwiring to the AC Output port 3 is required. 
Do not plug surge-protected power bars into the unit’s 120 VAC outlets. The surge protected 
components on the surge-protected power bar may not like the modified sinewave output 
generated by the inverter. 
Some appliances like speed controllers found in some fans, power tools and some power tools’ 
AC charger may not like the modified sinewave generated by the inverter. Those appliances may 
not work or may be damaged if they are connected to the inverter. If you are unsure about 
powering a device with the inverter, contact the manufacturer of the device. 
 
Estimated Run Time 
Following run times are estimates for reference, based on using different battery bank sizes. 
Actual run times may vary.  

Estimate run time on different 12V Battery Bank Size 

 

AC Load 

60AH  120AH 180AH 240AH 300AH 

50 W 

11 hrs. 

22 hrs. 

33 hrs. 

44 hrs. 

55 hrs. 

100 W 

5 hrs. 

11.5 hrs. 

17 hrs. 

23 hrs. 

29 hrs. 

200 W 

2.5 hrs. 

5 hrs. 

8 hrs. 

11 hrs. 

13.5 hrs. 

500 W 

49 mins 

2 hrs. 

3 hrs. 

4 hrs. 

5 hrs. 

1000 W 

15 mins 

49 mins 

1.5 hrs. 

2 hrs. 

2.5 hrs. 

1500 W 

8 mins 

27 mins 

49 mins 

1 hr 

1.5 hrs 

2000 W 

N.R. 

15 mins 

34 mins 

49 mins 

1 hrs 

2500 W 

N.R. 

11 mins 

25 mins 

37 mins 

49 mins 

3000 W 

N.R. 

N.R. 

17 mins 

27 mins 

37 mins 

         Note: N.R. - Not Recommended 

 
 

5. FEATURE 

SETTING 

To understand more about the unit features, read the following section and follow the instructions 
to make desired changes to the setting. 

 
Understanding the Unit Settings 

Battery Under Voltage Setting 

SdL 

Battery under voltage protection setting is set to LOW (used for normal operation) 
     Under voltage alarm:                  11.0 Vdc 
     Under voltage alarm recovery:   11.3 Vdc 
     Under voltage shutdown:           

 

10.5 Vdc 

     Under voltage recovery:             

 

12.0 Vdc 

SdH 

Battery under voltage protection setting is set to HIGH (setting to avoid battery over 
discharge, this setting is used when the inverter is connected to the car start battery) 
     Under voltage alarm:                  12.1 Vdc 
     Under voltage alarm recovery:   

 

12.3 Vdc 

     Under voltage shutdown:            11.8 Vdc 
     Under voltage recovery:             

 

12.6 Vdc 

Alarm Setting 

Summary of Contents for 3000W - 120V

Page 1: ...DC to AC Power Inverter Hardwire Version 3000W 120V MW1230HW Owner s Manual...

Page 2: ...n has been taken to ensure the accuracy of the contents of this guide KISAE Technology assumes no responsibility for errors or omissions Note as well that specifications and product functionality may...

Page 3: ...Page 3 Table of Contents 1 INTRODUCTION 4 2 PRODUCT DESCRIPTION 5 3 INSTALLATION 5 4 UNIT OPERATION 8 5 FEATURE SETTING 9 6 TROUBLESHOOTING 11 7 SPECIFICATIONS 11 8 WARRANTY 12...

Page 4: ...rs cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention Batteries produce explosive gases DO NOT smoke or have an open spark or fire near the system Keep unit...

Page 5: ...o not use in connection with life support systems or other medical equipment or devices 2 PRODUCT DESCRIPTION The Inverter includes the items list below Inverter base unit with detachable Remote Panel...

Page 6: ...wire with maximum cable length of 5 feet Important Use of smaller gauge cable or longer cable length may cause the inverter to shutdown under heavy load and may also melt the cable insulation and cat...

Page 7: ...ve DC input cable to one of the terminals of the Disconnect Switch Connect a DC input cable between the other terminal of the Disconnect Switch and one side of the terminal of the fuse holder Connect...

Page 8: ...nction during normal operation A beep sound will occur every time when the Power or Select button is triggered Power button function Turns inverter On Off Press and hold for 1 second to turn unit ON o...

Page 9: ...inverter contact the manufacturer of the device Estimated Run Time Following run times are estimates for reference based on using different battery bank sizes Actual run times may vary Estimate run t...

Page 10: ...button for 1 second to enter Individual Function Set Menu and you can make changes to the settings The unit will EXIT the Main Menu automatically if Power and Select buttons are not triggered for mor...

Page 11: ...400W AC Output Current 25 0A AC Surge Power Peak 6000W AC Output Voltage Frequency 120VAC 60 Hz AC Output Waveform Modified Sinewave Nominal DC Input Voltage 12 VDC No Load battery draw 1 2 ADC DC Inp...

Page 12: ...to retail store After speaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original...

Reviews: