Kisae 3000W - 120V Owner'S Manual Download Page 6

 

 

 

 

Page 

 

Preparing for Installation 

Typical Wiring block diagram of the Power Inverter: 
 
 
 
 
 
 
 
12V Battery Bank: 

  The use of a deep cycle battery is highly recommended for power inverter application 

  For battery size, you need to identify what you wish to operate, and for how long. It is 

recommended that you purchase as much battery capacity as possible. See more on Battery 
Run Time in Section 4. 

 
DC Fuse or Circuit Breaker:   

  DC-rated fuse or DC-rated circuit breaker connected along the DC positive line is required. 

Select a fuse or circuit breaker with a minimum of 450 Adc 

  Based on the size of your 12V Battery Bank, determine the overall short circuit current rating of 

the battery bank from the battery manufacturer. The fuse or circuit breaker chosen has to be 
able to withstand the short circuit current that may be generated by the battery bank 

 
DC Disconnect Switch: 

  Select a DC Disconnect Switch with the same or higher rating of the selected fuse or circuit 

breaker. 

  The DC Disconnect Switch is used to disconnect the DC power between the unit and the battery 

bank during service, maintenance or trouble shooting. 

 
DC Input Cable Size: 

  Use of isolated multi-strand low resistance wire is required for all the DC connections between 

the unit and the battery bank. 

  Use minimum #4/0 AWG wire with maximum cable length of 5 feet. 

Important: Use of smaller gauge cable or longer cable length may cause the inverter to shutdown 
under heavy load and may also melt the cable insulation and catch fire and can result in death or 
serious injury. 
 

 

Grounding Cable Size: 

Important: The unit is grounded through the ground stud located near the DC Input terminal and 
the chassis of the unit has to be grounded properly before use. 

  For Marine application, the DC grounding cable size may be one size smaller than the minimum 

size conductor required for the DC current-carrying conductors and the conductor is no smaller 
than #10AWG.  

  For Recreational Vehicle or Caravan application, the unit has to be grounded to the vehicle 

chassis with a minimum #8 AWG copper conductor. 

 

Installing the Inverter System 
WARNING

Electrical Shock Hazard

 

The unit ‘On/Off’ switch does not disconnect the DC power from the battery. Use the DC 
Disconnect Switch or disconnect the DC input cables to disconnect the DC power from the 
battery before working on any circuits connected to the unit. Failure to follow these 
instructions can result in death or serious injury. 
 
Installation: 

  Choose an appropriate mounting location.  

  For indoor use, the unit can be mounted in any direction except with the DC Input panel facing 

downwards. 

  Use the mounting template below to mark the positions of the mounting screws. 

 

Inverter 

DC Disconnect 

Switch 

Fuse or Circuit 

Breaker 

 
 
12 V Battery Bank 
 
 

 

AC Output 

Ports & 

USB Output  

Summary of Contents for 3000W - 120V

Page 1: ...DC to AC Power Inverter Hardwire Version 3000W 120V MW1230HW Owner s Manual...

Page 2: ...n has been taken to ensure the accuracy of the contents of this guide KISAE Technology assumes no responsibility for errors or omissions Note as well that specifications and product functionality may...

Page 3: ...Page 3 Table of Contents 1 INTRODUCTION 4 2 PRODUCT DESCRIPTION 5 3 INSTALLATION 5 4 UNIT OPERATION 8 5 FEATURE SETTING 9 6 TROUBLESHOOTING 11 7 SPECIFICATIONS 11 8 WARRANTY 12...

Page 4: ...rs cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention Batteries produce explosive gases DO NOT smoke or have an open spark or fire near the system Keep unit...

Page 5: ...o not use in connection with life support systems or other medical equipment or devices 2 PRODUCT DESCRIPTION The Inverter includes the items list below Inverter base unit with detachable Remote Panel...

Page 6: ...wire with maximum cable length of 5 feet Important Use of smaller gauge cable or longer cable length may cause the inverter to shutdown under heavy load and may also melt the cable insulation and cat...

Page 7: ...ve DC input cable to one of the terminals of the Disconnect Switch Connect a DC input cable between the other terminal of the Disconnect Switch and one side of the terminal of the fuse holder Connect...

Page 8: ...nction during normal operation A beep sound will occur every time when the Power or Select button is triggered Power button function Turns inverter On Off Press and hold for 1 second to turn unit ON o...

Page 9: ...inverter contact the manufacturer of the device Estimated Run Time Following run times are estimates for reference based on using different battery bank sizes Actual run times may vary Estimate run t...

Page 10: ...button for 1 second to enter Individual Function Set Menu and you can make changes to the settings The unit will EXIT the Main Menu automatically if Power and Select buttons are not triggered for mor...

Page 11: ...400W AC Output Current 25 0A AC Surge Power Peak 6000W AC Output Voltage Frequency 120VAC 60 Hz AC Output Waveform Modified Sinewave Nominal DC Input Voltage 12 VDC No Load battery draw 1 2 ADC DC Inp...

Page 12: ...to retail store After speaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original...

Reviews: