Kisae 3000W - 120V Owner'S Manual Download Page 7

 

 

 

 

Page 

 

  Drill the 4 mounting holes and place the Inverter in position and fasten the unit to the mounting 

surface. 

 

 

 

 

 
Chassis Grounding Connection: 

DANGER:

 The unit chassis has to be grounded properly. Never operate the Inverter 

without proper grounding. Failure to do so will result in death or serious injury. 

  Connect the grounding cable’s ring terminal to the unit ground screw. 

  Connect the other side of the cable to the common grounding point. 

 Important: Field wiring DC terminals tightening torque 12-13 Nm. 

 
DC Input Connection: 

CAUTION

: Reversing the DC Input terminal will damage the unit and it cannot be repaired. 

Damage caused by reverse polarity connection is not covered by the warranty.  

  Connect one end of the negative DC input cable to the Inverter DC negative terminal. Connect 

the other end of the cable to the battery negative terminal. 

  Make sure the Disconnect Switch is in the OFF position. 

  Connect one end of the positive DC input cable to the Power Inverter DC positive terminal. 

  Connect the other end of the positive DC input cable to one of the terminals of the Disconnect 

Switch. 

  Connect a DC input cable between the other terminal of the Disconnect Switch and one side of 

the terminal of the fuse holder. 

  Connect a DC input cable between the other terminal of the fuse holder and the battery positive 

terminal. 

  Install the selected fuse to the fuse holder. 

  Turn Disconnect Switch to ON position. 

 
AC Output Connections:  

CAUTION: P

lease be sure that the DC disconnect switch is turned OFF. 

 
The AC Output has two types of AC connections: 
1) 

Use of the provided AC sockets – NEMA 5-20 (Port 1 and 2) for AC load: 
This configuration does not require AC Output installation. Plug in the AC load to the provided 
AC output sockets. Each AC output port (Port 1 and 2) is limited to 20A and each port is 
protected by it’s 20A supplementary breaker.  

2) 

Use of the provided Hardwire AC Output terminal (Port 3). 

  Remove the 4 screws that secure the AC compartment cover located on the front panel of 

the unit. 

  Hardwire the AC load or any external AC socket to the AC Output ports 3. Please verify 

the Line ‘L’ and NEUTRAL ‘N’ connection on the AC Output ports. The AC Output port can 
provide the maximum power of 3000W, 25A AC current.  

  Re-install the AC compartment cover. 

 

Summary of Contents for 3000W - 120V

Page 1: ...DC to AC Power Inverter Hardwire Version 3000W 120V MW1230HW Owner s Manual...

Page 2: ...n has been taken to ensure the accuracy of the contents of this guide KISAE Technology assumes no responsibility for errors or omissions Note as well that specifications and product functionality may...

Page 3: ...Page 3 Table of Contents 1 INTRODUCTION 4 2 PRODUCT DESCRIPTION 5 3 INSTALLATION 5 4 UNIT OPERATION 8 5 FEATURE SETTING 9 6 TROUBLESHOOTING 11 7 SPECIFICATIONS 11 8 WARRANTY 12...

Page 4: ...rs cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention Batteries produce explosive gases DO NOT smoke or have an open spark or fire near the system Keep unit...

Page 5: ...o not use in connection with life support systems or other medical equipment or devices 2 PRODUCT DESCRIPTION The Inverter includes the items list below Inverter base unit with detachable Remote Panel...

Page 6: ...wire with maximum cable length of 5 feet Important Use of smaller gauge cable or longer cable length may cause the inverter to shutdown under heavy load and may also melt the cable insulation and cat...

Page 7: ...ve DC input cable to one of the terminals of the Disconnect Switch Connect a DC input cable between the other terminal of the Disconnect Switch and one side of the terminal of the fuse holder Connect...

Page 8: ...nction during normal operation A beep sound will occur every time when the Power or Select button is triggered Power button function Turns inverter On Off Press and hold for 1 second to turn unit ON o...

Page 9: ...inverter contact the manufacturer of the device Estimated Run Time Following run times are estimates for reference based on using different battery bank sizes Actual run times may vary Estimate run t...

Page 10: ...button for 1 second to enter Individual Function Set Menu and you can make changes to the settings The unit will EXIT the Main Menu automatically if Power and Select buttons are not triggered for mor...

Page 11: ...400W AC Output Current 25 0A AC Surge Power Peak 6000W AC Output Voltage Frequency 120VAC 60 Hz AC Output Waveform Modified Sinewave Nominal DC Input Voltage 12 VDC No Load battery draw 1 2 ADC DC Inp...

Page 12: ...to retail store After speaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original...

Reviews: